Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-4

JELD-WEN, inc. — Premium Atlantic Vinyl Single Hung · Single Hung

EPA ENERGY STAR Version 7.0 certifies 408 variants inside JELD-WEN, inc. Premium Atlantic Vinyl Single Hung, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.13 to 0.29. Qualifying for North-Central, South-Central, Southern, this Single Hung family places #1,174 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.25
SHGC Range
0.13-0.29
Certified Options
408
Category Standing
#1,174 of 1,352

How does JELD-WEN, inc. Premium Atlantic Vinyl Single Hung compare thermally against Window peers?

JELD-WEN, inc. Premium Atlantic Vinyl Single Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Premium Atlantic Vinyl Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Premium Atlantic Vinyl Single Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Premium Atlantic Vinyl Single Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Premium Atlantic Vinyl Single Hung is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.25-0.32.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2026-04-13. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 408 certified glazing combinations for Premium Atlantic Vinyl Single Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 16 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 70 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 400 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Atlantic Vinyl Single Hung appear below.

Where does JELD-WEN, inc. Premium Atlantic Vinyl Single Hung stand thermally among ENERGY STAR Window lines?

Testing puts JELD-WEN, inc. Premium Atlantic Vinyl Single Hung at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 408 configurations. Solar heat gain ranges between 0.13 and 0.29 across North-Central, South-Central, Southern.

Which glazing options in JELD-WEN, inc. Premium Atlantic Vinyl Single Hung meet Northern climate limits?

JELD-WEN, inc. Premium Atlantic Vinyl Single Hung holds zero Northern Zone qualifications (min U 0.25). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How does a 3x5 ft Premium Atlantic Vinyl Single Hung window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Premium Atlantic Vinyl Single Hung at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Premium Atlantic Vinyl Single Hung the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Atlantic Vinyl Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install JELD-WEN, inc. Premium Atlantic Vinyl Single Hung in Southern or South-Central zones?

Across North-Central, South-Central, Southern, 400 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Premium Atlantic Vinyl Single Hung, while total line SHGC reaches 0.29 in colder packages.

Are all 408 Premium Atlantic Vinyl Single Hung configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 408 Premium Atlantic Vinyl Single Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect Premium Atlantic Vinyl Single Hung?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Premium Atlantic Vinyl Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on Premium Atlantic Vinyl Single Hung?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code JEL and product line JEL-A-4, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Atlantic Vinyl Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros