Window · Vinyl Frame NFRC ANL · Product Line ANL-A-10

Anlin Industries — Coronado/Monte Verde/Bayview/Extreme Awning · Awning (Projected)

Across 14 Anlin Industries certified families, Coronado/Monte Verde/Bayview/Extreme Awning supplies 495 Awning, Projected configurations starting at 0.25 U-Factor and 0.11 SHGC for North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.39 SHGC. Its thermal floor ranks #1,174 of 1,352 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.11-0.39
Certified Options
495
Category Standing
#1,174 of 1,352

How does Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning compare thermally against Window peers?

Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Coronado/Monte Verde/Bayview/Extreme AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Coronado/Monte Verde/Bayview/Extreme Awning (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Coronado/Monte Verde/Bayview/Extreme Awning Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning standing at #1,174 of 1,352 certified Window product series, tied with 81 others at 0.25, more insulating than 7.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.06 before selecting Low-E tiers.

Climate coverage for Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2017-12-11 licensing and 2024-02-14 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 495 certified glazing combinations for Coronado/Monte Verde/Bayview/Extreme Awning (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 68 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 273 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 489 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Anlin Industries produce?

Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning appear below.

How well does Coronado/Monte Verde/Bayview/Extreme Awning by Anlin Industries insulate relative to Window benchmarks?

Testing puts Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 495 configurations. Solar heat gain ranges between 0.11 and 0.39 across North-Central, South-Central, Southern.

Which glazing options in Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning meet Northern climate limits?

No. Because Coronado/Monte Verde/Bayview/Extreme Awning reaches only 0.25 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

What conductive BTU/hr difference separates Coronado/Monte Verde/Bayview/Extreme Awning from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Coronado/Monte Verde/Bayview/Extreme Awning at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning?

Do not specify Coronado/Monte Verde/Bayview/Extreme Awning without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Coronado/Monte Verde/Bayview/Extreme Awning options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning in Southern or South-Central zones?

Yes, Coronado/Monte Verde/Bayview/Extreme Awning holds 489 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

Does Coronado/Monte Verde/Bayview/Extreme Awning carry EPA Most Efficient certification across its lineup?

All 495 Coronado/Monte Verde/Bayview/Extreme Awning listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 Coronado/Monte Verde/Bayview/Extreme Awning installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Coronado/Monte Verde/Bayview/Extreme Awning installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Coronado/Monte Verde/Bayview/Extreme Awning glass specs on job sites?

Verify NFRC ID ANL and series ANL-A-10 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Anlin Industries Coronado/Monte Verde/Bayview/Extreme Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros