Window · Vinyl / Wood Frame NFRC KOI · Product Line KOI-A-70 ENERGY STAR Most Efficient Eligible

Kohltech International, Ltd. — S-100 Transom · Transom

Positioning #136/1,352 in certified Window, Kohltech International, Ltd. S-100 Transom pairs Vinyl / Wood frame construction with 46 glazing options rated between 0.23 and 0.55 SHGC across Northern, North-Central, South-Central, Southern. Across 21 certified Kohltech International, Ltd. product families, its thermal resistance spans 0.15 to 0.26 U-Factor and the line includes 22 ENERGY STAR Most Efficient packages (47.8% of line).

Min U-Factor
0.15
SHGC Range
0.23-0.55
Certified Options
46
Category Standing
#136 of 1,352

How does Kohltech International, Ltd. S-100 Transom compare thermally against Window peers?

Kohltech International, Ltd. S-100 Transom achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. S-100 TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing S-100 Transom (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

S-100 Transom Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across S-100 Transom spans 46 NFRC test records (KOI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at +0.01 against the Vinyl / Wood median (0.14).

Regional qualification covers Northern, North-Central, South-Central, Southern. 22 configurations meet ENERGY STAR Most Efficient criteria while 44 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-02-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 46 certified glazing combinations for S-100 Transom (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 44 packages (22 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 20 packages (10 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2 packages (2 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2 packages (2 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
OKNA Windows & Doors Mfg — 410 Picture Window Vinyl 0.15 0.16 56
Vector Windows — Envision Casement Picture Vinyl 0.15 0.18 57
OKNA Windows & Doors Mfg — 7500 Double Hung Vinyl 0.15 0.15 59
Fibertec Window and Door Group — 300 Awning Fiberglass 0.15 0.14 61
Fibertec Window and Door Group — 300 Casement Fiberglass 0.15 0.14 63

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. S-100 Transom appear below.

Where does Kohltech International, Ltd. S-100 Transom stand thermally among ENERGY STAR Window lines?

Kohltech International, Ltd. S-100 Transom spans 46 certified configurations with U-Factors between 0.15 and 0.26 and SHGC values from 0.23 to 0.55. Ranked #136 of 1,352 Window families, it carries 22 Most Efficient options.

How does Kohltech International, Ltd. S-100 Transom satisfy Version 7.0 Northern criteria?

Kohltech International, Ltd. S-100 Transom supplies 44 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.26, so inspect the NFRC order sheet before purchase.

What BTU/hr heat transfer results from S-100 Transom's 0.15 minimum U-Factor?

At U 0.15, a standard 3x5 ft (15 sq ft) S-100 Transom opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.

When should a buyer skip Kohltech International, Ltd. S-100 Transom and compare alternatives?

Do not specify S-100 Transom without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on S-100 Transom options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does S-100 Transom meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 2 Southern-approved options within S-100 Transom spanning SHGC down to 0.23. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside S-100 Transom qualifies as Most Efficient?

Only 22 options out of 46 (47.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kohltech International, Ltd. S-100 Transom, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 S-100 Transom window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kohltech International, Ltd. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify S-100 Transom after sticker removal?

Verify NFRC ID KOI and series KOI-A-70 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. S-100 Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros