Kohltech International, Ltd. — S-100 Transom · Transom
Positioning #136/1,352 in certified Window, Kohltech International, Ltd. S-100 Transom pairs Vinyl / Wood frame construction with 46 glazing options rated between 0.23 and 0.55 SHGC across Northern, North-Central, South-Central, Southern. Across 21 certified Kohltech International, Ltd. product families, its thermal resistance spans 0.15 to 0.26 U-Factor and the line includes 22 ENERGY STAR Most Efficient packages (47.8% of line).
- Min U-Factor
- 0.15
- SHGC Range
- 0.23-0.55
- Certified Options
- 46
- Category Standing
- #136 of 1,352
How does Kohltech International, Ltd. S-100 Transom compare thermally against Window peers?
Kohltech International, Ltd. S-100 Transom achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across S-100 Transom spans 46 NFRC test records (KOI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at +0.01 against the Vinyl / Wood median (0.14).
Regional qualification covers Northern, North-Central, South-Central, Southern. 22 configurations meet ENERGY STAR Most Efficient criteria while 44 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-02-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 46 certified glazing combinations for S-100 Transom (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 44 packages (22 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 20 packages (10 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 2 packages (2 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 2 packages (2 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| OKNA Windows & Doors Mfg — 410 Picture Window | Vinyl | 0.15 | 0.16 | 56 |
| Vector Windows — Envision Casement Picture | Vinyl | 0.15 | 0.18 | 57 |
| OKNA Windows & Doors Mfg — 7500 Double Hung | Vinyl | 0.15 | 0.15 | 59 |
| Fibertec Window and Door Group — 300 Awning | Fiberglass | 0.15 | 0.14 | 61 |
| Fibertec Window and Door Group — 300 Casement | Fiberglass | 0.15 | 0.14 | 63 |
What other certified series does Kohltech International, Ltd. produce?
Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Fiberglass Entry Door
U-Factor 0.15–0.28 · 331,883 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. S-100 Transom appear below.
Where does Kohltech International, Ltd. S-100 Transom stand thermally among ENERGY STAR Window lines?
Kohltech International, Ltd. S-100 Transom spans 46 certified configurations with U-Factors between 0.15 and 0.26 and SHGC values from 0.23 to 0.55. Ranked #136 of 1,352 Window families, it carries 22 Most Efficient options.
How does Kohltech International, Ltd. S-100 Transom satisfy Version 7.0 Northern criteria?
Kohltech International, Ltd. S-100 Transom supplies 44 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.26, so inspect the NFRC order sheet before purchase.
What BTU/hr heat transfer results from S-100 Transom's 0.15 minimum U-Factor?
At U 0.15, a standard 3x5 ft (15 sq ft) S-100 Transom opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.
When should a buyer skip Kohltech International, Ltd. S-100 Transom and compare alternatives?
Do not specify S-100 Transom without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on S-100 Transom options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does S-100 Transom meet Southern hot-climate SHGC caps (<= 0.23)?
Warm-climate homeowners have 2 Southern-approved options within S-100 Transom spanning SHGC down to 0.23. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside S-100 Transom qualifies as Most Efficient?
Only 22 options out of 46 (47.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kohltech International, Ltd. S-100 Transom, usually requiring triple-pane or upgraded Low-E coatings.
What federal compliance checks govern 2026 S-100 Transom window swaps?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kohltech International, Ltd. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
What permanent glass etch marks verify S-100 Transom after sticker removal?
Verify NFRC ID KOI and series KOI-A-70 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. S-100 Transom come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)