Kohltech International, Ltd. — Select Fixed Casement · Picture Window
Across 21 Kohltech International, Ltd. certified families, Select Fixed Casement supplies 50 Picture Window configurations starting at 0.15 U-Factor and 0.20 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.26 U-Factor and 0.55 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.15
- SHGC Range
- 0.20-0.55
- Certified Options
- 50
- Category Standing
- #136 of 1,352
How does Kohltech International, Ltd. Select Fixed Casement compare thermally against Window peers?
Kohltech International, Ltd. Select Fixed Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kohltech International, Ltd. Select Fixed Casement at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.20-0.55 band.
Mapping NFRC SHGC values (0.20 to 0.55) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 24 configurations meet ENERGY STAR Most Efficient criteria while 32 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors KOI to 2024-09-19 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 50 certified glazing combinations for Select Fixed Casement (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 32 packages (24 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 32 packages (14 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 6 packages (6 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 6 packages (6 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| OKNA Windows & Doors Mfg — 410 Picture Window | Vinyl | 0.15 | 0.16 | 56 |
| Vector Windows — Envision Casement Picture | Vinyl | 0.15 | 0.18 | 57 |
| OKNA Windows & Doors Mfg — 7500 Double Hung | Vinyl | 0.15 | 0.15 | 59 |
| Mathews Brothers Company — Sanford Hills Fixed Casement | Vinyl | 0.15 | 0.24 | 64 |
| OKNA Windows & Doors Mfg — 7520 Double Slider | Vinyl | 0.15 | 0.15 | 68 |
What other certified series does Kohltech International, Ltd. produce?
Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Fiberglass Entry Door
U-Factor 0.15–0.28 · 331,883 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. Select Fixed Casement appear below.
What U-Factor and SHGC range does Kohltech International, Ltd. Select Fixed Casement achieve?
EPA ENERGY STAR v7.0 records 50 configurations for Kohltech International, Ltd. Select Fixed Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.15 versus a 0.20 Window median. Only 24 options earn Most Efficient status.
Which glazing options in Kohltech International, Ltd. Select Fixed Casement meet Northern climate limits?
Yes. 32 packages in Kohltech International, Ltd. Select Fixed Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.
How do you calculate winter heat conduction for Kohltech International, Ltd. Select Fixed Casement?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Select Fixed Casement at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What homeowner profiles are a poor match for Kohltech International, Ltd. Select Fixed Casement?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Select Fixed Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Is Select Fixed Casement suitable for sunbelt cooling-dominated homes?
Yes. 6 Southern-certified options inside Kohltech International, Ltd. Select Fixed Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.55 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in Select Fixed Casement holds Most Efficient recognition?
Only 24 options out of 50 (48.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kohltech International, Ltd. Select Fixed Casement, usually requiring triple-pane or upgraded Low-E coatings.
What 2026 federal tax credit and Lead RRP rules apply to Select Fixed Casement?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do you cross-check NFRC KOI and product line KOI-A-68 on delivery?
Verify NFRC ID KOI and series KOI-A-68 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. Select Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)