Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-277

Kolbe and Kolbe Millwork Co., Inc — Ultra Double Hung Sash Set Transom Extruded(UED5E1642) · Picture Window

Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.24 across 410 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.43.

Min U-Factor
0.24
SHGC Range
0.11-0.43
Certified Options
410
Category Standing
#1,034 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultra Double Hung Sash Set Transom Extruded(UED5E1642)Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Ultra Double Hung Sash Set Transom Extruded(UED5E1642) (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultra Double Hung Sash Set Transom Extruded(UED5E1642) Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultra Double Hung Sash Set Transom Extruded(UED5E1642) spans 410 NFRC test records (KKM), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.03 against the Wood median (0.21).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors KKM to 2024-08-08 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 410 certified glazing combinations for Ultra Double Hung Sash Set Transom Extruded(UED5E1642) (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 1 package (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 71 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 195 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 393 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) appear below.

How efficient is Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) compared with peer Window models?

EPA ENERGY STAR v7.0 records 410 configurations for Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) qualify for the ENERGY STAR Northern Zone?

While Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) misses the <= 0.22 prescriptive mark (floor U 0.24), 1 package still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How does a 3x5 ft Ultra Double Hung Sash Set Transom Extruded(UED5E1642) window perform under a 40 deg F temperature drop?

At U 0.24, a standard 3x5 ft (15 sq ft) Ultra Double Hung Sash Set Transom Extruded(UED5E1642) opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

Which situations make Ultra Double Hung Sash Set Transom Extruded(UED5E1642) the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Double Hung Sash Set Transom Extruded(UED5E1642) options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) in Southern or South-Central zones?

Yes, Ultra Double Hung Sash Set Transom Extruded(UED5E1642) holds 393 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

How many Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 410 Ultra Double Hung Sash Set Transom Extruded(UED5E1642) options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Do 2026 Ultra Double Hung Sash Set Transom Extruded(UED5E1642) installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC KKM and product line KKM-N-277 on delivery?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.11-0.43) against permit drawings for line KKM-N-277. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Sash Set Transom Extruded(UED5E1642) come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros