Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-64

Andersen Corporation — 400 Series Frenchwood® Patio Door Sidelight · Sidelite

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight spans 396 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code AND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.10 and 0.30.

Min U-Factor
0.24
SHGC Range
0.10-0.30
Certified Options
396
Category Standing
#1,034 of 1,352

How does Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight compare thermally against Window peers?

Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Frenchwood® Patio Door SidelightHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 400 Series Frenchwood® Patio Door Sidelight (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Frenchwood® Patio Door Sidelight Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), 400 Series Frenchwood® Patio Door Sidelight reaches 0.24 on its lowest-conductivity package — #280 of 408 in Wood, tied with 38 others at 0.24, more insulating than 22.1% of Wood lines (+0.03 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.28 down toward 0.24.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 130 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2024-03-20.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 396 certified glazing combinations for 400 Series Frenchwood® Patio Door Sidelight (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 130 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 130 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 374 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 374 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight appear below.

What thermal performance numbers separate Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight from peers?

Testing puts Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight at rank #1,034 of 1,352 Window entries with U 0.24 to 0.28 across 396 configurations. Solar heat gain ranges between 0.10 and 0.30 across Northern, North-Central, South-Central, Southern.

Which glazing options in Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight meet Northern climate limits?

Northern qualification on 400 Series Frenchwood® Patio Door Sidelight relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 130 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What conductive BTU/hr difference separates 400 Series Frenchwood® Patio Door Sidelight from the 0.22 Northern rule?

At U 0.24, a standard 3x5 ft (15 sq ft) 400 Series Frenchwood® Patio Door Sidelight opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

Which situations make 400 Series Frenchwood® Patio Door Sidelight the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Frenchwood® Patio Door Sidelight options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 400 Series Frenchwood® Patio Door Sidelight meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 374 Southern-approved options within 400 Series Frenchwood® Patio Door Sidelight spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does 400 Series Frenchwood® Patio Door Sidelight carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside 400 Series Frenchwood® Patio Door Sidelight's 396 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 400 Series Frenchwood® Patio Door Sidelight window swaps?

Any 400 Series Frenchwood® Patio Door Sidelight purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC AND and product line AND-N-64 on delivery?

Verify NFRC ID AND and series AND-N-64 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Frenchwood® Patio Door Sidelight come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)