Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-117

Windsor Windows and Doors — Pinnacle Clad Double Hung Picture · Picture Window

Across 82 Windsor Windows and Doors certified families, Pinnacle Clad Double Hung Picture supplies 454 Picture Window configurations starting at 0.24 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.47 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.14-0.47
Certified Options
454
Category Standing
#1,034 of 1,352

How does Windsor Windows and Doors Pinnacle Clad Double Hung Picture compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Clad Double Hung Picture achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Clad Double Hung PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Pinnacle Clad Double Hung Picture (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Clad Double Hung Picture Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Pinnacle Clad Double Hung Picture is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 6 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 454 certified glazing combinations for Pinnacle Clad Double Hung Picture (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 6 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 22 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 118 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 446 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Double Hung Picture appear below.

How well does Pinnacle Clad Double Hung Picture by Windsor Windows and Doors insulate relative to Window benchmarks?

Windsor Windows and Doors Pinnacle Clad Double Hung Picture spans 454 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.14 to 0.47. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Windsor Windows and Doors Pinnacle Clad Double Hung Picture meet Northern climate limits?

Northern qualification on Pinnacle Clad Double Hung Picture relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 6 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What BTU/hr heat transfer results from Pinnacle Clad Double Hung Picture's 0.24 minimum U-Factor?

Using NFRC WIN U-Factor 0.24, a 15 sq ft Fixed Window (FIXD) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

When should a buyer skip Windsor Windows and Doors Pinnacle Clad Double Hung Picture and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Double Hung Picture options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Is Pinnacle Clad Double Hung Picture suitable for sunbelt cooling-dominated homes?

Yes, Pinnacle Clad Double Hung Picture holds 446 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

Are all 454 Pinnacle Clad Double Hung Picture configurations ENERGY STAR Most Efficient?

No. Zero of the 454 configurations in Windsor Windows and Doors Pinnacle Clad Double Hung Picture hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 Pinnacle Clad Double Hung Picture window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Pinnacle Clad Double Hung Picture installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Clad Double Hung Picture units match permits?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.14-0.47) against permit drawings for line WIN-N-117. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Double Hung Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros