Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-182

Andersen Corporation — E-Series Fixed Casement Window - Direct-Set (1 Piece) · Picture Window

EPA ENERGY STAR Version 7.0 certifies 494 variants inside Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece), combining Wood frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.08 to 0.50. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #1,034 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.24
SHGC Range
0.08-0.50
Certified Options
494
Category Standing
#1,034 of 1,352

How does Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) compare thermally against Window peers?

Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E-Series Fixed Casement Window - Direct-Set (1 Piece)Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing E-Series Fixed Casement Window - Direct-Set (1 Piece) (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E-Series Fixed Casement Window - Direct-Set (1 Piece) Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) at rank #1,034 of 1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.08-0.50 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 12 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2026-03-12 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 494 certified glazing combinations for E-Series Fixed Casement Window - Direct-Set (1 Piece) (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 45 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 126 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 465 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) appear below.

How well does E-Series Fixed Casement Window - Direct-Set (1 Piece) by Andersen Corporation insulate relative to Window benchmarks?

Testing puts Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) at rank #1,034 of 1,352 Window entries with U 0.24 to 0.32 across 494 configurations. Solar heat gain ranges between 0.08 and 0.50 across Northern, North-Central, South-Central, Southern.

Can homeowners install E-Series Fixed Casement Window - Direct-Set (1 Piece) in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above E-Series Fixed Casement Window - Direct-Set (1 Piece)'s 0.24 minimum. However, 12 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How much winter heat loss does E-Series Fixed Casement Window - Direct-Set (1 Piece) conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on E-Series Fixed Casement Window - Direct-Set (1 Piece)'s lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Who should NOT choose Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Fixed Casement Window - Direct-Set (1 Piece) options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) in Southern or South-Central zones?

Exactly 465 E-Series Fixed Casement Window - Direct-Set (1 Piece) options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.08 rather than higher 0.50 glass.

Which package tier in E-Series Fixed Casement Window - Direct-Set (1 Piece) holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 494 E-Series Fixed Casement Window - Direct-Set (1 Piece) options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect E-Series Fixed Casement Window - Direct-Set (1 Piece)?

Any E-Series Fixed Casement Window - Direct-Set (1 Piece) purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) units match permits?

Verify NFRC ID AND and series AND-N-182 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Fixed Casement Window - Direct-Set (1 Piece) come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros