Pella Corporation — Pella Architect Reserve Double Hung - Wood - Model 5 · Double Hung
With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 spans 456 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code PEL, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.11 and 0.48.
- Min U-Factor
- 0.24
- SHGC Range
- 0.11-0.48
- Certified Options
- 456
- Category Standing
- #1,034 of 1,352
How does Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 compare thermally against Window peers?
Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.03 before selecting Low-E tiers.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 30 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2024-12-19 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 456 certified glazing combinations for Pella Architect Reserve Double Hung - Wood - Model 5 (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 30 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 62 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 164 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 400 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Double Hung Picture | Wood | 0.24 | 0.14 | 454 |
| Marvin — Elevate Double Hung | Wood | 0.24 | 0.13 | 460 |
| Weather Shield Mfg., Inc. — 8122 Double Hung | Wood | 0.24 | 0.11 | 485 |
| Andersen Corporation — E-Series Fixed Casement Window - Direct-Set (1 Piece) | Wood | 0.24 | 0.08 | 494 |
| Windsor Windows and Doors — Revive Legend Win-Pac | Wood | 0.24 | 0.11 | 494 |
What other certified series does Pella Corporation produce?
Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Pella Entry Doors - Wood Edge Steel Door
U-Factor 0.13–0.28 · 76,045 certified options.
250 Series / Power Symphony Fixed
U-Factor 0.14–0.32 · 266 certified options.
250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement
U-Factor 0.15–0.32 · 144 certified options.
Architect Wood Fixed Casement
U-Factor 0.15–0.32 · 2,468 certified options.
Pella Entry Doors - Fiberglass Skin Door
U-Factor 0.15–0.28 · 242,982 certified options.
Pella Entry Doors - Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 319,127 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 appear below.
Where does Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 stand thermally among ENERGY STAR Window lines?
Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 spans 456 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.11 to 0.48. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
Which glazing options in Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 meet Northern climate limits?
Prescriptive Northern approval ends at U <= 0.22, above Pella Architect Reserve Double Hung - Wood - Model 5's 0.24 minimum. However, 30 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
What BTU/hr heat transfer results from Pella Architect Reserve Double Hung - Wood - Model 5's 0.24 minimum U-Factor?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on Pella Architect Reserve Double Hung - Wood - Model 5's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
When should a buyer skip Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 and compare alternatives?
Skip Pella Architect Reserve Double Hung - Wood - Model 5 if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Reserve Double Hung - Wood - Model 5 options exceeding U 0.22.
How many Pella Architect Reserve Double Hung - Wood - Model 5 glazing packages pass Southern solar-heat rules?
Exactly 400 Pella Architect Reserve Double Hung - Wood - Model 5 options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.48 glass.
Which package tier in Pella Architect Reserve Double Hung - Wood - Model 5 holds Most Efficient recognition?
Zero glazing builds inside Pella Architect Reserve Double Hung - Wood - Model 5's 456 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
Do 2026 Pella Architect Reserve Double Hung - Wood - Model 5 installations qualify for IRS Section 25C tax credits?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Pella Architect Reserve Double Hung - Wood - Model 5 retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How can homeowners confirm delivered Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 units match permits?
Verify NFRC ID PEL and series PEL-N-234 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Reserve Double Hung - Wood - Model 5 come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)