Skip to main content
Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-483

Marvin — Infinity Insert Single Hung Round Top · Single Hung

Across 105 Marvin certified families, Infinity Insert Single Hung Round Top supplies 386 Single Hung configurations starting at 0.25 U-Factor and 0.17 SHGC for North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.23 SHGC. Its thermal floor ranks #1,174 of 1,352 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.17-0.23
Certified Options
386
Category Standing
#1,174 of 1,352

How does Marvin Infinity Insert Single Hung Round Top compare thermally against Window peers?

Marvin Infinity Insert Single Hung Round Top achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Infinity Insert Single Hung Round TopHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Infinity Insert Single Hung Round Top (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Infinity Insert Single Hung Round Top Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Infinity Insert Single Hung Round Top spans 386 NFRC test records (MAR), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Fiberglass median (0.19).

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-04-24.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 386 certified glazing combinations for Infinity Insert Single Hung Round Top (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 44 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 164 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 386 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Insert Single Hung Round Top appear below.

How efficient is Marvin Infinity Insert Single Hung Round Top compared with peer Window models?

Marvin Infinity Insert Single Hung Round Top spans 386 certified configurations with U-Factors between 0.25 and 0.32 and SHGC values from 0.17 to 0.23. Ranked #1,174 of 1,352 Window families, it carries 0 Most Efficient options.

Does Marvin Infinity Insert Single Hung Round Top qualify for the ENERGY STAR Northern Zone?

No—with 0 Northern packages and a 0.25 thermal floor, Marvin Infinity Insert Single Hung Round Top targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

How do you calculate winter heat conduction for Marvin Infinity Insert Single Hung Round Top?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.25 U-Factor yields 150.0 BTU/hr conductive transfer (+13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Marvin Infinity Insert Single Hung Round Top and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Insert Single Hung Round Top options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Infinity Insert Single Hung Round Top?

Warm-climate homeowners have 386 Southern-approved options within Infinity Insert Single Hung Round Top spanning SHGC down to 0.17. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Infinity Insert Single Hung Round Top holds Most Efficient recognition?

Zero glazing builds inside Infinity Insert Single Hung Round Top's 386 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

How do the 25C sunset and pre-1978 Lead RRP rules affect Infinity Insert Single Hung Round Top?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Infinity Insert Single Hung Round Top retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on Infinity Insert Single Hung Round Top?

Match the NFRC thermal sticker for code MAR and line MAR-N-483 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Insert Single Hung Round Top come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros