Skip to main content
Window · Wood Frame NFRC MAR · Product Line MAR-N-359

Marvin — Ultimate Casement Narrow Frame Push Out · Casement Windows

Across 105 Marvin certified families, Ultimate Casement Narrow Frame Push Out supplies 2,863 Casement Windows configurations starting at 0.27 U-Factor and 0.11 SHGC for South-Central, Southern, reaching up to 0.32 U-Factor and 0.23 SHGC. Its thermal floor ranks #1,292 of 1,352 category entries—0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.27
SHGC Range
0.11-0.23
Certified Options
2,863
Category Standing
#1,292 of 1,352

How does Marvin Ultimate Casement Narrow Frame Push Out compare thermally against Window peers?

Marvin Ultimate Casement Narrow Frame Push Out achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Casement Narrow Frame Push OutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Ultimate Casement Narrow Frame Push Out (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Casement Narrow Frame Push Out Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Ultimate Casement Narrow Frame Push Out reaches 0.27 on its lowest-conductivity package — #377 of 408 in Wood, tied with 17 others at 0.27, more insulating than 3.4% of Wood lines (+0.06 vs Wood peers). Pairing NFRC ID MAR across multi-pane fills shifts U-Factor from 0.32 down toward 0.27.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-10-11. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.27 conducts 162.0 BTU/hr (+30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,863 certified glazing combinations for Ultimate Casement Narrow Frame Push Out (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 496 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,863 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Casement Narrow Frame Push Out appear below.

How well does Ultimate Casement Narrow Frame Push Out by Marvin insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 2,863 configurations for Marvin Ultimate Casement Narrow Frame Push Out covering South-Central, Southern, dropping down to U 0.27 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Marvin Ultimate Casement Narrow Frame Push Out qualify for the ENERGY STAR Northern Zone?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.27). Focus on South-Central, Southern glazing applications where SHGC 0.11-0.23 manages cooling loads.

How do you calculate winter heat conduction for Marvin Ultimate Casement Narrow Frame Push Out?

At U 0.27, a standard 3x5 ft (15 sq ft) Ultimate Casement Narrow Frame Push Out opening transfers 162.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +30.0 BTU/hr difference.

What are the practical limitations of specifying Ultimate Casement Narrow Frame Push Out?

Skip Ultimate Casement Narrow Frame Push Out if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Casement Narrow Frame Push Out options exceeding U 0.22.

Can you install Marvin Ultimate Casement Narrow Frame Push Out in Southern or South-Central zones?

Across South-Central, Southern, 2,863 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Ultimate Casement Narrow Frame Push Out, while total line SHGC reaches 0.23 in colder packages.

Which package tier in Ultimate Casement Narrow Frame Push Out holds Most Efficient recognition?

Ultimate Casement Narrow Frame Push Out holds zero Most Efficient entries across its 2,863 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Do 2026 Ultimate Casement Narrow Frame Push Out installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Ultimate Casement Narrow Frame Push Out installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on Ultimate Casement Narrow Frame Push Out?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-359, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Casement Narrow Frame Push Out come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)