Skip to main content
Window · Wood Frame NFRC MAR · Product Line MAR-N-353

Marvin — Ultimate Casement Narrow Frame Push Out Picture · Picture Window

Marvin engineered the Ultimate Casement Narrow Frame Push Out Picture Picture Window line for North-Central, South-Central, Southern, certifying 3,735 glass-spacer combinations from 0.24 to 0.32 U-Factor and 0.11 to 0.33 SHGC. Relative to other Wood models tracked under NFRC MAR, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.11-0.33
Certified Options
3,735
Category Standing
#1,034 of 1,352

How does Marvin Ultimate Casement Narrow Frame Push Out Picture compare thermally against Window peers?

Marvin Ultimate Casement Narrow Frame Push Out Picture achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Casement Narrow Frame Push Out PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Ultimate Casement Narrow Frame Push Out Picture (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Casement Narrow Frame Push Out Picture Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultimate Casement Narrow Frame Push Out Picture spans 3,735 NFRC test records (MAR), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.03 against the Wood median (0.21).

Mapping NFRC SHGC values (0.11 to 0.33) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-10-11.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,735 certified glazing combinations for Ultimate Casement Narrow Frame Push Out Picture (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 782 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,443 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,379 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Casement Narrow Frame Push Out Picture appear below.

How well does Ultimate Casement Narrow Frame Push Out Picture by Marvin insulate relative to Window benchmarks?

Across 3,735 tested NFRC glazing configurations, Marvin Ultimate Casement Narrow Frame Push Out Picture with Wood framing and Fixed Window (FIXD) style reaches a 0.24 minimum U-Factor and 0.11-0.33 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

How does Marvin Ultimate Casement Narrow Frame Push Out Picture satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.24 thermal floor, Marvin Ultimate Casement Narrow Frame Push Out Picture targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

How much winter heat loss does Ultimate Casement Narrow Frame Push Out Picture conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Marvin Ultimate Casement Narrow Frame Push Out Picture and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Casement Narrow Frame Push Out Picture options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Is Ultimate Casement Narrow Frame Push Out Picture suitable for sunbelt cooling-dominated homes?

Yes, Ultimate Casement Narrow Frame Push Out Picture holds 3,379 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

How many Marvin Ultimate Casement Narrow Frame Push Out Picture variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside Ultimate Casement Narrow Frame Push Out Picture's 3,735 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Marvin Ultimate Casement Narrow Frame Push Out Picture in 2026?

Any Ultimate Casement Narrow Frame Push Out Picture purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Ultimate Casement Narrow Frame Push Out Picture?

Confirm both the paper NFRC label and permanent corner glass etch match line MAR-N-353 and NFRC ID MAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Casement Narrow Frame Push Out Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)