Andersen Corporation — 400 Series Tilt-Wash Double-Hung Transom Insert Window · Picture Window
EPA ENERGY STAR Version 7.0 certifies 1,218 variants inside Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window, combining Wood frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.15 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #1,034 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.24
- SHGC Range
- 0.15-0.49
- Certified Options
- 1,218
- Category Standing
- #1,034 of 1,352
How does Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window compare thermally against Window peers?
Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 400 Series Tilt-Wash Double-Hung Transom Insert Window is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.
Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 42 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2025-09-18 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,218 certified glazing combinations for 400 Series Tilt-Wash Double-Hung Transom Insert Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 42 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 235 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 521 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,088 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Custom Clad Wood Casement Pushout | Wood | 0.24 | 0.11 | 961 |
| JELD-WEN, inc. — Custom Clad Epic Plus Casement | Wood | 0.24 | 0.11 | 914 |
| Windsor Windows and Doors — Revive Clad Pocket Casement | Wood | 0.24 | 0.15 | 805 |
| Windsor Windows and Doors — Revive Clad Pocket Awning | Wood | 0.24 | 0.15 | 782 |
| JELD-WEN, inc. — Custom Clad Epic Double Hung Picture | Wood | 0.24 | 0.10 | 755 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window appear below.
Where does Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window stand thermally among ENERGY STAR Window lines?
Built with Wood framing in Fixed Window (FIXD) style, Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window offers 1,218 Version 7.0 configurations from U 0.24 up to 0.32, posting +0.04 against the Window median of 0.20 with 0 Most Efficient picks.
Which glazing options in Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window meet Northern climate limits?
Northern qualification on 400 Series Tilt-Wash Double-Hung Transom Insert Window relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 42 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How much winter heat loss does 400 Series Tilt-Wash Double-Hung Transom Insert Window conduct across a 15 sq ft opening?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400 Series Tilt-Wash Double-Hung Transom Insert Window at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
When should a buyer skip Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window and compare alternatives?
Do not specify 400 Series Tilt-Wash Double-Hung Transom Insert Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Tilt-Wash Double-Hung Transom Insert Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Can you install Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window in Southern or South-Central zones?
Exactly 1,088 400 Series Tilt-Wash Double-Hung Transom Insert Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.49 glass.
Does 400 Series Tilt-Wash Double-Hung Transom Insert Window carry EPA Most Efficient certification across its lineup?
ENERGY STAR Most Efficient designation is absent across all 1,218 400 Series Tilt-Wash Double-Hung Transom Insert Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Do 2026 400 Series Tilt-Wash Double-Hung Transom Insert Window installations qualify for IRS Section 25C tax credits?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 400 Series Tilt-Wash Double-Hung Transom Insert Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do building inspectors verify 400 Series Tilt-Wash Double-Hung Transom Insert Window glass specs on job sites?
Match the NFRC thermal sticker for code AND and line AND-N-134 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Insert Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)