Window · Wood Frame NFRC JEL · Product Line JEL-N-829

JELD-WEN, inc. — Custom Clad Epic Plus Casement · Casement Windows

JELD-WEN, inc. engineered the Custom Clad Epic Plus Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 914 glass-spacer combinations from 0.24 to 0.32 U-Factor and 0.11 to 0.38 SHGC. Relative to other Wood models tracked under NFRC JEL, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.11-0.38
Certified Options
914
Category Standing
#1,034 of 1,352

How does JELD-WEN, inc. Custom Clad Epic Plus Casement compare thermally against Window peers?

JELD-WEN, inc. Custom Clad Epic Plus Casement achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Custom Clad Epic Plus CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Custom Clad Epic Plus Casement (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Custom Clad Epic Plus Casement Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Custom Clad Epic Plus Casement is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-02-28 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 914 certified glazing combinations for Custom Clad Epic Plus Casement (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 20 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 90 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 904 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Clad Epic Plus Casement appear below.

Where does JELD-WEN, inc. Custom Clad Epic Plus Casement stand thermally among ENERGY STAR Window lines?

Testing puts JELD-WEN, inc. Custom Clad Epic Plus Casement at rank #1,034 of 1,352 Window entries with U 0.24 to 0.32 across 914 configurations. Solar heat gain ranges between 0.11 and 0.38 across Northern, North-Central, South-Central, Southern.

Can homeowners install Custom Clad Epic Plus Casement in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above Custom Clad Epic Plus Casement's 0.24 minimum. However, 2 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How much winter heat loss does Custom Clad Epic Plus Casement conduct across a 15 sq ft opening?

At U 0.24, a standard 3x5 ft (15 sq ft) Custom Clad Epic Plus Casement opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

What are the practical limitations of specifying Custom Clad Epic Plus Casement?

Skip Custom Clad Epic Plus Casement if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Clad Epic Plus Casement options exceeding U 0.22.

Does Custom Clad Epic Plus Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 904 Custom Clad Epic Plus Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.38 glass.

Are all 914 Custom Clad Epic Plus Casement configurations ENERGY STAR Most Efficient?

Custom Clad Epic Plus Casement holds zero Most Efficient entries across its 914 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on JELD-WEN, inc. Custom Clad Epic Plus Casement in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 JELD-WEN, inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered JELD-WEN, inc. Custom Clad Epic Plus Casement units match permits?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.11-0.38) against permit drawings for line JEL-N-829. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Clad Epic Plus Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)