Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-181

Windsor Windows and Doors — Revive Clad Pocket Casement · Casement Windows

Positioning #1,034/1,352 in certified Window, Windsor Windows and Doors Revive Clad Pocket Casement pairs Wood frame construction with 805 glazing options rated between 0.15 and 0.44 SHGC across Northern, North-Central, South-Central, Southern. Across 82 certified Windsor Windows and Doors product families, its thermal resistance spans 0.24 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.15-0.44
Certified Options
805
Category Standing
#1,034 of 1,352

How does Windsor Windows and Doors Revive Clad Pocket Casement compare thermally against Window peers?

Windsor Windows and Doors Revive Clad Pocket Casement achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Revive Clad Pocket CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Revive Clad Pocket Casement (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Revive Clad Pocket Casement Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Revive Clad Pocket Casement reaches 0.24 on its lowest-conductivity package — #280 of 408 in Wood, tied with 38 others at 0.24, more insulating than 22.1% of Wood lines (+0.03 vs Wood peers). Pairing NFRC ID WIN across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 16 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors WIN to 2024-02-20 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 805 certified glazing combinations for Revive Clad Pocket Casement (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 16 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 55 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 262 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 783 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Revive Clad Pocket Casement appear below.

What U-Factor and SHGC range does Windsor Windows and Doors Revive Clad Pocket Casement achieve?

EPA ENERGY STAR v7.0 records 805 configurations for Windsor Windows and Doors Revive Clad Pocket Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in Windsor Windows and Doors Revive Clad Pocket Casement meet Northern climate limits?

While Windsor Windows and Doors Revive Clad Pocket Casement misses the <= 0.22 prescriptive mark (floor U 0.24), 16 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How do you calculate winter heat conduction for Windsor Windows and Doors Revive Clad Pocket Casement?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Revive Clad Pocket Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Revive Clad Pocket Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Revive Clad Pocket Casement suitable for sunbelt cooling-dominated homes?

Yes, Revive Clad Pocket Casement holds 783 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

Are all 805 Revive Clad Pocket Casement configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 805 Revive Clad Pocket Casement options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Do 2026 Revive Clad Pocket Casement installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Revive Clad Pocket Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on Revive Clad Pocket Casement?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-181, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Revive Clad Pocket Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros