Window · Wood Frame NFRC JEL · Product Line JEL-N-708

JELD-WEN, inc. — Custom Clad Wood Casement Pushout · Casement Windows

JELD-WEN, inc. Custom Clad Wood Casement Pushout is a Casement Windows assembly with a Wood frame that reaches a minimum U-Factor of 0.24 across 961 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.38.

Min U-Factor
0.24
SHGC Range
0.11-0.38
Certified Options
961
Category Standing
#1,034 of 1,352

How does JELD-WEN, inc. Custom Clad Wood Casement Pushout compare thermally against Window peers?

JELD-WEN, inc. Custom Clad Wood Casement Pushout achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Custom Clad Wood Casement PushoutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Custom Clad Wood Casement Pushout (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Custom Clad Wood Casement Pushout Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Custom Clad Wood Casement Pushout is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame with Metal-Clad Wood sash. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-08-08 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 961 certified glazing combinations for Custom Clad Wood Casement Pushout (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 20 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 85 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 951 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Clad Wood Casement Pushout appear below.

Where does JELD-WEN, inc. Custom Clad Wood Casement Pushout stand thermally among ENERGY STAR Window lines?

JELD-WEN, inc. Custom Clad Wood Casement Pushout spans 961 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.11 to 0.38. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Does JELD-WEN, inc. Custom Clad Wood Casement Pushout qualify for the ENERGY STAR Northern Zone?

With a 0.24 minimum U-Factor, JELD-WEN, inc. Custom Clad Wood Casement Pushout cannot satisfy prescriptive <= 0.22 Northern targets, yet 2 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What BTU/hr heat transfer results from Custom Clad Wood Casement Pushout's 0.24 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose JELD-WEN, inc. Custom Clad Wood Casement Pushout for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Clad Wood Casement Pushout options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Does Custom Clad Wood Casement Pushout meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 951 Southern-approved options within Custom Clad Wood Casement Pushout spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Custom Clad Wood Casement Pushout holds Most Efficient recognition?

Custom Clad Wood Casement Pushout holds zero Most Efficient entries across its 961 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Do 2026 Custom Clad Wood Casement Pushout installations qualify for IRS Section 25C tax credits?

Any Custom Clad Wood Casement Pushout purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Custom Clad Wood Casement Pushout?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code JEL and product line JEL-N-708, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Clad Wood Casement Pushout come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros