Andersen Corporation — 400 Series Woodwright® Double-Hung Picture Insert Window · Picture Window
EPA ENERGY STAR Version 7.0 certifies 1,670 variants inside Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window, combining Wood frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.15 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #1,034 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.24
- SHGC Range
- 0.15-0.49
- Certified Options
- 1,670
- Category Standing
- #1,034 of 1,352
How does Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window compare thermally against Window peers?
Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 400 Series Woodwright® Double-Hung Picture Insert Window is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.
Mapping NFRC SHGC values (0.15 to 0.49) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 44 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2025-09-17 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,670 certified glazing combinations for 400 Series Woodwright® Double-Hung Picture Insert Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 44 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 358 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 741 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,472 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Custom Clad Wood Casement Pushout | Wood | 0.24 | 0.11 | 961 |
| JELD-WEN, inc. — Custom Clad Epic Plus Casement | Wood | 0.24 | 0.11 | 914 |
| Windsor Windows and Doors — Revive Clad Pocket Casement | Wood | 0.24 | 0.15 | 805 |
| Windsor Windows and Doors — Revive Clad Pocket Awning | Wood | 0.24 | 0.15 | 782 |
| JELD-WEN, inc. — Custom Clad Epic Double Hung Picture | Wood | 0.24 | 0.10 | 755 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window appear below.
How efficient is Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window compared with peer Window models?
Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window spans 1,670 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.15 to 0.49. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
How does Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window satisfy Version 7.0 Northern criteria?
While Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window misses the <= 0.22 prescriptive mark (floor U 0.24), 44 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.
How do you calculate winter heat conduction for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 400 Series Woodwright® Double-Hung Picture Insert Window's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
When should a buyer skip Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window and compare alternatives?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Woodwright® Double-Hung Picture Insert Window options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
Can you install Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window in Southern or South-Central zones?
Exactly 1,472 400 Series Woodwright® Double-Hung Picture Insert Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.49 glass.
Which package tier in 400 Series Woodwright® Double-Hung Picture Insert Window holds Most Efficient recognition?
All 1,670 400 Series Woodwright® Double-Hung Picture Insert Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Woodwright® Double-Hung Picture Insert Window?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How can homeowners confirm delivered Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window units match permits?
Verify NFRC ID AND and series AND-N-77 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)