Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-77

Andersen Corporation — 400 Series Woodwright® Double-Hung Picture Insert Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 1,670 variants inside Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window, combining Wood frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.15 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #1,034 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.24
SHGC Range
0.15-0.49
Certified Options
1,670
Category Standing
#1,034 of 1,352

How does Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window compare thermally against Window peers?

Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Woodwright® Double-Hung Picture Insert WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 400 Series Woodwright® Double-Hung Picture Insert Window (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Woodwright® Double-Hung Picture Insert Window Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 400 Series Woodwright® Double-Hung Picture Insert Window is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Mapping NFRC SHGC values (0.15 to 0.49) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 44 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2025-09-17 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,670 certified glazing combinations for 400 Series Woodwright® Double-Hung Picture Insert Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 44 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 358 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 741 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,472 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window appear below.

How efficient is Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window compared with peer Window models?

Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window spans 1,670 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.15 to 0.49. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

How does Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window satisfy Version 7.0 Northern criteria?

While Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window misses the <= 0.22 prescriptive mark (floor U 0.24), 44 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How do you calculate winter heat conduction for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 400 Series Woodwright® Double-Hung Picture Insert Window's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Woodwright® Double-Hung Picture Insert Window options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Can you install Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window in Southern or South-Central zones?

Exactly 1,472 400 Series Woodwright® Double-Hung Picture Insert Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.49 glass.

Which package tier in 400 Series Woodwright® Double-Hung Picture Insert Window holds Most Efficient recognition?

All 1,670 400 Series Woodwright® Double-Hung Picture Insert Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Woodwright® Double-Hung Picture Insert Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window units match permits?

Verify NFRC ID AND and series AND-N-77 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Insert Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)