Window · Wood Frame NFRC MAR · Product Line MAR-N-428 ENERGY STAR Most Efficient Eligible

Marvin — Ultimate Double Hung Transom G2 · Picture Window

Positioning #477/1,352 in certified Window, Marvin Ultimate Double Hung Transom G2 pairs Wood frame construction with 4,043 glazing options rated between 0.11 and 0.43 SHGC across Northern, North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.18 to 0.32 U-Factor and the line includes 188 ENERGY STAR Most Efficient packages (4.7% of line).

Min U-Factor
0.18
SHGC Range
0.11-0.43
Certified Options
4,043
Category Standing
#477 of 1,352

How does Marvin Ultimate Double Hung Transom G2 compare thermally against Window peers?

Marvin Ultimate Double Hung Transom G2 achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Double Hung Transom G2Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Ultimate Double Hung Transom G2 (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Double Hung Transom G2 Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Marvin Ultimate Double Hung Transom G2 at rank #477 of 1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.43 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 188 configurations meet ENERGY STAR Most Efficient criteria while 230 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2025-08-07.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,043 certified glazing combinations for Ultimate Double Hung Transom G2 (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 230 packages (72 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,556 packages (137 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,972 packages (89 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,283 packages (136 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Double Hung Transom G2 appear below.

How efficient is Marvin Ultimate Double Hung Transom G2 compared with peer Window models?

Built with Wood framing in Fixed Window (FIXD) style, Marvin Ultimate Double Hung Transom G2 offers 4,043 Version 7.0 configurations from U 0.18 up to 0.32, posting -0.02 against the Window median of 0.20 with 188 Most Efficient picks.

Does Marvin Ultimate Double Hung Transom G2 qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 230 Ultimate Double Hung Transom G2 packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from Ultimate Double Hung Transom G2's 0.18 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 108.0 BTU/hr on Ultimate Double Hung Transom G2's lowest-U package (0.18), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip Marvin Ultimate Double Hung Transom G2 and compare alternatives?

Skip Ultimate Double Hung Transom G2 if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Double Hung Transom G2 options exceeding U 0.22.

Is Ultimate Double Hung Transom G2 suitable for sunbelt cooling-dominated homes?

Yes. 3,283 Southern-certified options inside Marvin Ultimate Double Hung Transom G2 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.43 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 4,043 Ultimate Double Hung Transom G2 configurations ENERGY STAR Most Efficient?

EPA lists 188 Most Efficient options (4.7% share) inside Marvin Ultimate Double Hung Transom G2, out of 4,043 total Version 7.0 entries.

What federal compliance checks govern 2026 Ultimate Double Hung Transom G2 window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC MAR and product line MAR-N-428 on delivery?

Verify NFRC ID MAR and series MAR-N-428 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Double Hung Transom G2 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)