Andersen Corporation — A-Series Fixed Transom Window · Picture Window
Andersen Corporation engineered the A-Series Fixed Transom Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 5,832 glass-spacer combinations from 0.18 to 0.32 U-Factor and 0.12 to 0.48 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.18
- SHGC Range
- 0.12-0.48
- Certified Options
- 5,832
- Category Standing
- #477 of 1,352
How does Andersen Corporation A-Series Fixed Transom Window compare thermally against Window peers?
Andersen Corporation A-Series Fixed Transom Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across A-Series Fixed Transom Window spans 5,832 NFRC test records (AND), ranking #477 of 1,352 Window families (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%). Its 0.18 thermal floor compares at -0.03 against the Wood median (0.21).
Regional qualification covers Northern, North-Central, South-Central, Southern. 212 configurations meet ENERGY STAR Most Efficient criteria while 386 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2026-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 5,832 certified glazing combinations for A-Series Fixed Transom Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 386 packages (78 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,277 packages (156 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 2,684 packages (96 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 5,185 packages (150 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Ultimate Double Hung Transom G2 | Wood | 0.18 | 0.11 | 4,043 |
| Weather Shield Mfg., Inc. — 6121 Double Hung Transom | Wood | 0.18 | 0.11 | 2,658 |
| Marvin — Ultimate Glider | Wood | 0.18 | 0.11 | 9,660 |
| Sierra Pacific Windows — H3 2.0 Direct Set | Wood | 0.18 | 0.11 | 1,846 |
| JELD-WEN, inc. — Custom Clad Direct Set Geometric | Wood | 0.18 | 0.13 | 1,453 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Fixed Transom Window appear below.
What U-Factor and SHGC range does Andersen Corporation A-Series Fixed Transom Window achieve?
Testing puts Andersen Corporation A-Series Fixed Transom Window at rank #477 of 1,352 Window entries with U 0.18 to 0.32 across 5,832 configurations. Solar heat gain ranges between 0.12 and 0.48 across Northern, North-Central, South-Central, Southern.
Is A-Series Fixed Transom Window approved for Northern Zone heating climates?
Prescriptive Northern compliance covers 386 A-Series Fixed Transom Window packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.
How much winter heat loss does A-Series Fixed Transom Window conduct across a 15 sq ft opening?
At U 0.18, a standard 3x5 ft (15 sq ft) A-Series Fixed Transom Window opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.
Who should NOT choose Andersen Corporation A-Series Fixed Transom Window for a residential project?
Skip A-Series Fixed Transom Window if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Fixed Transom Window options exceeding U 0.22.
Is A-Series Fixed Transom Window suitable for sunbelt cooling-dominated homes?
Exactly 5,185 A-Series Fixed Transom Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.48 glass.
Does A-Series Fixed Transom Window carry EPA Most Efficient certification across its lineup?
Not every package qualifies: 212 of 5,832 A-Series Fixed Transom Window glazing builds earn Most Efficient recognition (3.6%), while other variants sit on the standard Version 7.0 tier.
Can homeowners claim Form 5695 credits on Andersen Corporation A-Series Fixed Transom Window in 2026?
Any A-Series Fixed Transom Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify A-Series Fixed Transom Window after sticker removal?
Verify NFRC ID AND and series AND-N-89 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Fixed Transom Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)