Andersen Corporation — A-Series Fixed Transom Window · Picture Window

Andersen Corporation engineered the A-Series Fixed Transom Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 5,832 glass-spacer combinations from 0.18 to 0.32 U-Factor and 0.12 to 0.48 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.18
SHGC Range
0.12-0.48
Certified Options
5,832
Category Standing
#477 of 1,352

How does Andersen Corporation A-Series Fixed Transom Window compare thermally against Window peers?

Andersen Corporation A-Series Fixed Transom Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A-Series Fixed Transom WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing A-Series Fixed Transom Window (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A-Series Fixed Transom Window Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across A-Series Fixed Transom Window spans 5,832 NFRC test records (AND), ranking #477 of 1,352 Window families (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%). Its 0.18 thermal floor compares at -0.03 against the Wood median (0.21).

Regional qualification covers Northern, North-Central, South-Central, Southern. 212 configurations meet ENERGY STAR Most Efficient criteria while 386 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,832 certified glazing combinations for A-Series Fixed Transom Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 386 packages (78 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,277 packages (156 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,684 packages (96 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,185 packages (150 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Ultimate Double Hung Transom G2 Wood 0.18 0.11 4,043
Weather Shield Mfg., Inc. — 6121 Double Hung Transom Wood 0.18 0.11 2,658
Marvin — Ultimate Glider Wood 0.18 0.11 9,660
Sierra Pacific Windows — H3 2.0 Direct Set Wood 0.18 0.11 1,846
JELD-WEN, inc. — Custom Clad Direct Set Geometric Wood 0.18 0.13 1,453

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Fixed Transom Window appear below.

What U-Factor and SHGC range does Andersen Corporation A-Series Fixed Transom Window achieve?

Testing puts Andersen Corporation A-Series Fixed Transom Window at rank #477 of 1,352 Window entries with U 0.18 to 0.32 across 5,832 configurations. Solar heat gain ranges between 0.12 and 0.48 across Northern, North-Central, South-Central, Southern.

Is A-Series Fixed Transom Window approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 386 A-Series Fixed Transom Window packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How much winter heat loss does A-Series Fixed Transom Window conduct across a 15 sq ft opening?

At U 0.18, a standard 3x5 ft (15 sq ft) A-Series Fixed Transom Window opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

Who should NOT choose Andersen Corporation A-Series Fixed Transom Window for a residential project?

Skip A-Series Fixed Transom Window if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Fixed Transom Window options exceeding U 0.22.

Is A-Series Fixed Transom Window suitable for sunbelt cooling-dominated homes?

Exactly 5,185 A-Series Fixed Transom Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.48 glass.

Does A-Series Fixed Transom Window carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 212 of 5,832 A-Series Fixed Transom Window glazing builds earn Most Efficient recognition (3.6%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Andersen Corporation A-Series Fixed Transom Window in 2026?

Any A-Series Fixed Transom Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify A-Series Fixed Transom Window after sticker removal?

Verify NFRC ID AND and series AND-N-89 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Fixed Transom Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros