Skip to main content
Window · Wood Frame NFRC MAR · Product Line MAR-N-387 ENERGY STAR Most Efficient Eligible

Marvin — Ultimate Glider · Double Slider

With a minimum U-Factor of 0.18—-0.02 compared against the 0.20 Window median—Marvin Ultimate Glider spans 9,660 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MAR, the Wood assembly includes 2,876 ENERGY STAR Most Efficient packages (29.8% of line) and offers SHGC packages between 0.11 and 0.45.

Min U-Factor
0.18
SHGC Range
0.11-0.45
Certified Options
9,660
Category Standing
#477 of 1,352

How does Marvin Ultimate Glider compare thermally against Window peers?

Marvin Ultimate Glider achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate GliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Ultimate Glider (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Glider Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultimate Glider spans 9,660 NFRC test records (MAR), ranking #477 of 1,352 Window families (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%). Its 0.18 thermal floor compares at -0.03 against the Wood median (0.21).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 2,876 configurations meet ENERGY STAR Most Efficient criteria while 4,680 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-04-24.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 9,660 certified glazing combinations for Ultimate Glider (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 4,680 packages (1,389 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 7,373 packages (1,805 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 4,488 packages (987 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,502 packages (2,022 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Glider appear below.

Where does Marvin Ultimate Glider stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 9,660 configurations for Marvin Ultimate Glider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.20 Window median. Only 2,876 options earn Most Efficient status.

Does Marvin Ultimate Glider qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 4,680 compliant Northern packages inside Ultimate Glider, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from Ultimate Glider's 0.18 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Ultimate Glider at U 0.18 conducts 108.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Ultimate Glider the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Glider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Ultimate Glider?

Warm-climate homeowners have 5,502 Southern-approved options within Ultimate Glider spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside Ultimate Glider qualifies as Most Efficient?

No. Exactly 2,876 of 9,660 configurations (29.8%) earn ENERGY STAR Most Efficient status in Ultimate Glider; the remaining standard v7.0 options pass base zone limits only.

What federal compliance checks govern 2026 Ultimate Glider window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Marvin Ultimate Glider units match permits?

Match the NFRC thermal sticker for code MAR and line MAR-N-387 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Glider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros