Skip to main content
Window · Vinyl Frame NFRC MIL · Product Line MIL-A-178 ENERGY STAR Most Efficient Eligible

Milgard Manufacturing, Inc. — 6330.6330J.6340.6341 Fixed · Picture Window

Milgard Manufacturing, Inc. engineered the 6330.6330J.6340.6341 Fixed Picture Window line for Northern, North-Central, South-Central, Southern, certifying 7,659 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.10 to 0.58 SHGC. Relative to other Vinyl models tracked under NFRC MIL, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.10-0.58
Certified Options
7,659
Category Standing
#742 of 1,352

How does Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed compare thermally against Window peers?

Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6330.6330J.6340.6341 FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 6330.6330J.6340.6341 Fixed (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6330.6330J.6340.6341 Fixed Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 58 certified Milgard Manufacturing, Inc. series, this Picture Window offers a 0.11 U-Factor adjustment span between 0.32 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 592 configurations meet ENERGY STAR Most Efficient criteria while 2,450 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2025-04-03. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,659 certified glazing combinations for 6330.6330J.6340.6341 Fixed (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 2,450 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 4,115 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 3,526 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 4,627 packages (592 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed appear below.

What thermal performance numbers separate Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed from peers?

Across 7,659 tested NFRC glazing configurations, Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed with Vinyl framing and Fixed Window (FIXD) style reaches a 0.21 minimum U-Factor and 0.10-0.58 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.

Does Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 2,450 compliant Northern packages inside 6330.6330J.6340.6341 Fixed, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from 6330.6330J.6340.6341 Fixed's 0.21 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 6330.6330J.6340.6341 Fixed at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 6330.6330J.6340.6341 Fixed options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in 6330.6330J.6340.6341 Fixed?

Warm-climate homeowners have 4,627 Southern-approved options within 6330.6330J.6340.6341 Fixed spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed variants earn ENERGY STAR Most Efficient?

Within 6330.6330J.6340.6341 Fixed, 7.7% (592 of 7,659) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Can homeowners claim Form 5695 credits on Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed in 2026?

Any 6330.6330J.6340.6341 Fixed purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on 6330.6330J.6340.6341 Fixed?

Verify NFRC ID MIL and series MIL-A-178 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 6330.6330J.6340.6341 Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros