MI Windows and Doors, LLC — 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window · Single Hung
EPA ENERGY STAR Version 7.0 certifies 9,333 variants inside MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.33 and SHGC 0.13 to 0.53. Qualifying for Northern, North-Central, South-Central, Southern, this Single Hung family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.21
- SHGC Range
- 0.13-0.53
- Certified Options
- 9,333
- Category Standing
- #742 of 1,352
How does MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window compare thermally against Window peers?
MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.13-0.53 band.
Climate coverage for MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 127 configurations meet ENERGY STAR Most Efficient criteria while 251 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2024-04-12.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 9,333 certified glazing combinations for 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 251 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 2,261 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 4,763 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 8,565 packages (127 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Associated Materials, Inc. — A680 Direct Set | Vinyl | 0.21 | 0.08 | 8,855 |
| Milgard Manufacturing, Inc. — 2510T/2511T/2530T/2570T Fixed Casement | Vinyl | 0.21 | 0.09 | 9,978 |
| Milgard Manufacturing, Inc. — 6330.6330J.6340.6341 Fixed | Vinyl | 0.21 | 0.10 | 7,659 |
| Milgard Manufacturing, Inc. — HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window | Vinyl | 0.21 | 0.10 | 6,496 |
| Milgard Manufacturing, Inc. — 8225 Double Hung | Vinyl | 0.21 | 0.10 | 5,062 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window appear below.
What thermal performance numbers separate MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window from peers?
EPA ENERGY STAR v7.0 records 9,333 configurations for MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 127 options earn Most Efficient status.
How does MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window satisfy Version 7.0 Northern criteria?
Cold-climate buyers get 251 compliant Northern packages inside 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.33 options.
What BTU/hr heat transfer results from 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window's 0.21 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
Does 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window meet Southern hot-climate SHGC caps (<= 0.23)?
Across Northern, North-Central, South-Central, Southern, 8,565 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window, while total line SHGC reaches 0.53 in colder packages.
Which package tier in 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window holds Most Efficient recognition?
No. Exactly 127 of 9,333 configurations (1.4%) earn ENERGY STAR Most Efficient status in 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window; the remaining standard v7.0 options pass base zone limits only.
What federal compliance checks govern 2026 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window window swaps?
Any 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window after sticker removal?
Verify NFRC ID MEI and series MEI-A-56 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 3500/3540/3500 HP Polyvinyl Chloride (PVC) Single Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)