Window · Vinyl Frame NFRC MIL · Product Line MIL-A-304 ENERGY STAR Most Efficient Eligible

Milgard Manufacturing, Inc. — HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window · Awning (Projected)

With a minimum U-Factor of 0.21—+0.01 compared against the 0.20 Window median—Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window spans 6,496 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MIL, the Vinyl assembly includes 304 ENERGY STAR Most Efficient packages (4.7% of line) and offers SHGC packages between 0.10 and 0.41.

Min U-Factor
0.21
SHGC Range
0.10-0.41
Certified Options
6,496
Category Standing
#742 of 1,352

How does Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window compare thermally against Window peers?

Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. HM140|V450-40 Polyvinyl Chloride (PVC) Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 58 certified Milgard Manufacturing, Inc. series, this Awning, Projected offers a 0.11 U-Factor adjustment span between 0.32 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 304 configurations meet ENERGY STAR Most Efficient criteria while 452 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-06-25.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,496 certified glazing combinations for HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 452 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 3,459 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 4,586 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,672 packages (304 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window appear below.

How well does HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window by Milgard Manufacturing, Inc. insulate relative to Window benchmarks?

Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window spans 6,496 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.10 to 0.41. Ranked #742 of 1,352 Window families, it carries 304 Most Efficient options.

How does Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window satisfy Version 7.0 Northern criteria?

Yes, 452 packages satisfy Northern ENERGY STAR Version 7.0 rules in HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window's 0.21 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window and compare alternatives?

Skip HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window options exceeding U 0.22.

Does HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 5,672 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window, while total line SHGC reaches 0.41 in colder packages.

Does HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window carry EPA Most Efficient certification across its lineup?

Only 304 options out of 6,496 (4.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window, usually requiring triple-pane or upgraded Low-E coatings.

Do 2026 HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MIL and product line MIL-A-304, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. HM140|V450-40 Polyvinyl Chloride (PVC) Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)