Skip to main content
Window · Vinyl Frame NFRC MIL · Product Line MIL-A-303 ENERGY STAR Most Efficient Eligible

Milgard Manufacturing, Inc. — HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window · Casement Windows

Milgard Manufacturing, Inc. engineered the HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 6,267 glass-spacer combinations from 0.22 to 0.32 U-Factor and 0.10 to 0.41 SHGC. Relative to other Vinyl models tracked under NFRC MIL, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.10-0.41
Certified Options
6,267
Category Standing
#831 of 1,352

How does Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window compare thermally against Window peers?

Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window spans 6,267 NFRC test records (MIL), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 168 configurations meet ENERGY STAR Most Efficient criteria while 332 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-04-11 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,267 certified glazing combinations for HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 332 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 2,844 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 4,333 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,571 packages (168 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window appear below.

What thermal performance numbers separate Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window from peers?

Testing puts Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window at rank #831 of 1,352 Window entries with U 0.22 to 0.32 across 6,267 configurations. Solar heat gain ranges between 0.10 and 0.41 across Northern, North-Central, South-Central, Southern.

Which glazing options in Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window meet Northern climate limits?

Yes, 332 packages satisfy Northern ENERGY STAR Version 7.0 rules in HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window in Southern or South-Central zones?

Yes, HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window holds 5,571 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.

Are all 6,267 HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window configurations ENERGY STAR Most Efficient?

Only 168 options out of 6,267 (2.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window, usually requiring triple-pane or upgraded Low-E coatings.

Do 2026 HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window?

Match the NFRC thermal sticker for code MIL and line MIL-A-303 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. HM147|V450-47 Polyvinyl Chloride (PVC) (X, O) Casement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros