Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-173 ENERGY STAR Most Efficient Eligible

JELD-WEN, inc. — Builders Vinyl (V-2500) Fixed · Picture Window

EPA ENERGY STAR Version 7.0 certifies 6,625 variants inside JELD-WEN, inc. Builders Vinyl (V-2500) Fixed, combining Vinyl frame construction with U-Factors spanning 0.22 to 0.32 and SHGC 0.13 to 0.57. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #831 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.22
SHGC Range
0.13-0.57
Certified Options
6,625
Category Standing
#831 of 1,352

How does JELD-WEN, inc. Builders Vinyl (V-2500) Fixed compare thermally against Window peers?

JELD-WEN, inc. Builders Vinyl (V-2500) Fixed achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Builders Vinyl (V-2500) FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Builders Vinyl (V-2500) Fixed (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Builders Vinyl (V-2500) Fixed Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 61 certified JELD-WEN, inc. series, this Picture Window offers a 0.10 U-Factor adjustment span between 0.32 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).

Mapping NFRC SHGC values (0.13 to 0.57) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 114 configurations meet ENERGY STAR Most Efficient criteria while 827 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors JEL to 2024-02-10 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,625 certified glazing combinations for Builders Vinyl (V-2500) Fixed (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 827 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1,482 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2,378 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,165 packages (114 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Builders Vinyl (V-2500) Fixed appear below.

How efficient is JELD-WEN, inc. Builders Vinyl (V-2500) Fixed compared with peer Window models?

Across 6,625 tested NFRC glazing configurations, JELD-WEN, inc. Builders Vinyl (V-2500) Fixed with Vinyl framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.13-0.57 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

How does JELD-WEN, inc. Builders Vinyl (V-2500) Fixed satisfy Version 7.0 Northern criteria?

Yes. 827 packages in JELD-WEN, inc. Builders Vinyl (V-2500) Fixed clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates Builders Vinyl (V-2500) Fixed from the 0.22 Northern rule?

At U 0.22, a standard 3x5 ft (15 sq ft) Builders Vinyl (V-2500) Fixed opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

Which situations make Builders Vinyl (V-2500) Fixed the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Builders Vinyl (V-2500) Fixed options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Builders Vinyl (V-2500) Fixed glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 5,165 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Builders Vinyl (V-2500) Fixed, while total line SHGC reaches 0.57 in colder packages.

How many JELD-WEN, inc. Builders Vinyl (V-2500) Fixed variants earn ENERGY STAR Most Efficient?

EPA lists 114 Most Efficient options (1.7% share) inside JELD-WEN, inc. Builders Vinyl (V-2500) Fixed, out of 6,625 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect Builders Vinyl (V-2500) Fixed?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 JELD-WEN, inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify Builders Vinyl (V-2500) Fixed glass specs on job sites?

Verify NFRC ID JEL and series JEL-A-173 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Builders Vinyl (V-2500) Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros