Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-96 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — A770 Picture · Picture Window

Across 34 Associated Materials, Inc. certified families, A770 Picture supplies 3,534 Picture Window configurations starting at 0.22 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.56 SHGC. Its thermal floor ranks #831 of 1,352 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.09-0.56
Certified Options
3,534
Category Standing
#831 of 1,352

How does Associated Materials, Inc. A770 Picture compare thermally against Window peers?

Associated Materials, Inc. A770 Picture achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A770 PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing A770 Picture (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A770 Picture Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), A770 Picture is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.22-0.32.

Climate coverage for Associated Materials, Inc. A770 Picture spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 86 configurations meet ENERGY STAR Most Efficient criteria while 456 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2018-01-10 and cert timestamp 2024-07-30.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,534 certified glazing combinations for A770 Picture (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 456 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 840 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,543 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,812 packages (86 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A770 Picture appear below.

How efficient is Associated Materials, Inc. A770 Picture compared with peer Window models?

Built with Vinyl framing in Fixed Window (FIXD) style, Associated Materials, Inc. A770 Picture offers 3,534 Version 7.0 configurations from U 0.22 up to 0.32, posting +0.02 against the Window median of 0.20 with 86 Most Efficient picks.

Which glazing options in Associated Materials, Inc. A770 Picture meet Northern climate limits?

Yes, 456 packages satisfy Northern ENERGY STAR Version 7.0 rules in A770 Picture. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates A770 Picture from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on A770 Picture's lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip Associated Materials, Inc. A770 Picture and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on A770 Picture options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is A770 Picture suitable for sunbelt cooling-dominated homes?

Yes, A770 Picture holds 2,812 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.09 SHGC in cooling climates.

Which package tier in A770 Picture holds Most Efficient recognition?

Within A770 Picture, 2.4% (86 of 3,534) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Can homeowners claim Form 5695 credits on Associated Materials, Inc. A770 Picture in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC ASO and product line ASO-A-96 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ASO and product line ASO-A-96, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A770 Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros