Skip to main content
Window · Vinyl Frame NFRC WCW · Product Line WCW-M-25 ENERGY STAR Most Efficient Eligible

Wincore Window Company, LLC — Series 400, 500, 5400 Picture Window · Picture Window

With a minimum U-Factor of 0.22—+0.02 compared against the 0.20 Window median—Wincore Window Company, LLC Series 400, 500, 5400 Picture Window spans 1,398 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code WCW, the Vinyl assembly includes 52 ENERGY STAR Most Efficient packages (3.7% of line) and offers SHGC packages between 0.14 and 0.54.

Min U-Factor
0.22
SHGC Range
0.14-0.54
Certified Options
1,398
Category Standing
#831 of 1,352

How does Wincore Window Company, LLC Series 400, 500, 5400 Picture Window compare thermally against Window peers?

Wincore Window Company, LLC Series 400, 500, 5400 Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Series 400, 500, 5400 Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Series 400, 500, 5400 Picture Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Series 400, 500, 5400 Picture Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 23 certified Wincore Window Company, LLC series, this Picture Window offers a 0.10 U-Factor adjustment span between 0.32 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).

Climate coverage for Wincore Window Company, LLC Series 400, 500, 5400 Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 52 configurations meet ENERGY STAR Most Efficient criteria while 183 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2024-04-13. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,398 certified glazing combinations for Series 400, 500, 5400 Picture Window (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 183 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 355 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 892 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,263 packages (52 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC Series 400, 500, 5400 Picture Window appear below.

Where does Wincore Window Company, LLC Series 400, 500, 5400 Picture Window stand thermally among ENERGY STAR Window lines?

Across 1,398 tested NFRC glazing configurations, Wincore Window Company, LLC Series 400, 500, 5400 Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.14-0.54 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

How does Wincore Window Company, LLC Series 400, 500, 5400 Picture Window satisfy Version 7.0 Northern criteria?

Wincore Window Company, LLC Series 400, 500, 5400 Picture Window supplies 183 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

What conductive BTU/hr difference separates Series 400, 500, 5400 Picture Window from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Series 400, 500, 5400 Picture Window at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Wincore Window Company, LLC Series 400, 500, 5400 Picture Window and compare alternatives?

Do not specify Series 400, 500, 5400 Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Series 400, 500, 5400 Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Wincore Window Company, LLC Series 400, 500, 5400 Picture Window in Southern or South-Central zones?

Exactly 1,263 Series 400, 500, 5400 Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.54 glass.

Which package tier in Series 400, 500, 5400 Picture Window holds Most Efficient recognition?

No. Exactly 52 of 1,398 configurations (3.7%) earn ENERGY STAR Most Efficient status in Series 400, 500, 5400 Picture Window; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Series 400, 500, 5400 Picture Window?

Any Series 400, 500, 5400 Picture Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Wincore Window Company, LLC Series 400, 500, 5400 Picture Window units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WCW and product line WCW-M-25, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC Series 400, 500, 5400 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros