Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-704 ENERGY STAR Most Efficient Eligible

JELD-WEN, inc. — Builders Vinyl (V-2500) Double Hung Fixed Direct Set · Picture Window

Positioning #831/1,352 in certified Window, JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set pairs Vinyl frame construction with 3,593 glazing options rated between 0.14 and 0.57 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.22 to 0.32 U-Factor and the line includes 68 ENERGY STAR Most Efficient packages (1.9% of line).

Min U-Factor
0.22
SHGC Range
0.14-0.57
Certified Options
3,593
Category Standing
#831 of 1,352

How does JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set compare thermally against Window peers?

JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Builders Vinyl (V-2500) Double Hung Fixed Direct SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Builders Vinyl (V-2500) Double Hung Fixed Direct Set (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Builders Vinyl (V-2500) Double Hung Fixed Direct Set Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 68 configurations meet ENERGY STAR Most Efficient criteria while 562 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-06-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,593 certified glazing combinations for Builders Vinyl (V-2500) Double Hung Fixed Direct Set (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 562 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 800 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,404 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,740 packages (68 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set appear below.

How well does Builders Vinyl (V-2500) Double Hung Fixed Direct Set by JELD-WEN, inc. insulate relative to Window benchmarks?

JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set spans 3,593 certified configurations with U-Factors between 0.22 and 0.32 and SHGC values from 0.14 to 0.57. Ranked #831 of 1,352 Window families, it carries 68 Most Efficient options.

Is Builders Vinyl (V-2500) Double Hung Fixed Direct Set approved for Northern Zone heating climates?

Cold-climate buyers get 562 compliant Northern packages inside Builders Vinyl (V-2500) Double Hung Fixed Direct Set, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How much winter heat loss does Builders Vinyl (V-2500) Double Hung Fixed Direct Set conduct across a 15 sq ft opening?

At U 0.22, a standard 3x5 ft (15 sq ft) Builders Vinyl (V-2500) Double Hung Fixed Direct Set opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

What homeowner profiles are a poor match for JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Builders Vinyl (V-2500) Double Hung Fixed Direct Set options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Is Builders Vinyl (V-2500) Double Hung Fixed Direct Set suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 2,740 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set, while total line SHGC reaches 0.57 in colder packages.

Are all 3,593 Builders Vinyl (V-2500) Double Hung Fixed Direct Set configurations ENERGY STAR Most Efficient?

Only 68 options out of 3,593 (1.9%) meet tighter Most Efficient U-Factor and SHGC thresholds in JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to Builders Vinyl (V-2500) Double Hung Fixed Direct Set?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set units match permits?

Inspectors match the temporary NFRC sticker (U 0.22-0.32, SHGC 0.14-0.57) against permit drawings for line JEL-A-704. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Builders Vinyl (V-2500) Double Hung Fixed Direct Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros