Skip to main content
Window · Vinyl Frame NFRC NSM · Product Line NSM-A-19 ENERGY STAR Most Efficient Eligible

North Star Manufacturing (London) Ltd. — 1273 Double Slider Lift-Out · Double Slider

Positioning #671/1,352 in certified Window, North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out pairs Vinyl frame construction with 71 glazing options rated between 0.16 and 0.51 SHGC across Northern, North-Central, South-Central, Southern. Across 11 certified North Star Manufacturing (London) Ltd. product families, its thermal resistance spans 0.20 to 0.28 U-Factor and the line includes 5 ENERGY STAR Most Efficient packages (7.0% of line).

Min U-Factor
0.20
SHGC Range
0.16-0.51
Certified Options
71
Category Standing
#671 of 1,352

How does North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out compare thermally against Window peers?

North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1273 Double Slider Lift-OutHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 1273 Double Slider Lift-Out (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1273 Double Slider Lift-Out Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 1273 Double Slider Lift-Out spans 71 NFRC test records (NSM), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at +0.01 against the Vinyl median (0.19).

Climate coverage for North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 5 configurations meet ENERGY STAR Most Efficient criteria while 24 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-12-05.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 71 certified glazing combinations for 1273 Double Slider Lift-Out (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 24 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 28 packages (1 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 40 packages (1 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 40 packages (5 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
United Window & Door Mfg., Inc. — 9600 Horizontal Slider Vinyl 0.20 0.13 66
Soft-Lite, LLC — Elements DSL20 Slider Vinyl 0.20 0.17 60
Soft-Lite, LLC — Imperial Elite DSL12E Vinyl 0.20 0.17 60
Walsh Building Products — 6100 Double Slider Vinyl 0.20 0.18 59
Thompson Creek Window Company — 7900 Double Hung Vinyl 0.20 0.17 88

What other certified series does North Star Manufacturing (London) Ltd. produce?

Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out appear below.

What U-Factor and SHGC range does North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out achieve?

Testing puts North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out at rank #671 of 1,352 Window entries with U 0.20 to 0.28 across 71 configurations. Solar heat gain ranges between 0.16 and 0.51 across Northern, North-Central, South-Central, Southern.

Can homeowners install 1273 Double Slider Lift-Out in cold Northern ENERGY STAR counties?

Yes. 24 packages in North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How does a 3x5 ft 1273 Double Slider Lift-Out window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1273 Double Slider Lift-Out options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is 1273 Double Slider Lift-Out suitable for sunbelt cooling-dominated homes?

Yes, 1273 Double Slider Lift-Out holds 40 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

Does 1273 Double Slider Lift-Out carry EPA Most Efficient certification across its lineup?

Only 5 options out of 71 (7.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to 1273 Double Slider Lift-Out?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1273 Double Slider Lift-Out retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify 1273 Double Slider Lift-Out after sticker removal?

Verify NFRC ID NSM and series NSM-A-19 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros