Skip to main content
Window · Vinyl Frame NFRC NSM · Product Line NSM-A-14 ENERGY STAR Most Efficient Eligible

North Star Manufacturing (London) Ltd. — 1372/1374 Single Slider/3-Lite End Vent · Single Slider

Positioning #671/1,352 in certified Window, North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent pairs Vinyl frame construction with 73 glazing options rated between 0.16 and 0.54 SHGC across Northern, North-Central, South-Central, Southern. Across 11 certified North Star Manufacturing (London) Ltd. product families, its thermal resistance spans 0.20 to 0.28 U-Factor and the line includes 5 ENERGY STAR Most Efficient packages (6.8% of line).

Min U-Factor
0.20
SHGC Range
0.16-0.54
Certified Options
73
Category Standing
#671 of 1,352

How does North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent compare thermally against Window peers?

North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1372/1374 Single Slider/3-Lite End VentHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 1372/1374 Single Slider/3-Lite End Vent (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1372/1374 Single Slider/3-Lite End Vent Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 11 certified North Star Manufacturing (London) Ltd. series, this Single Slider offers a 0.08 U-Factor adjustment span between 0.28 entry options and 0.20 top-performing glazing. Category standing is #671/1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 5 configurations meet ENERGY STAR Most Efficient criteria while 31 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.20 U-Factor yields 120.0 BTU/hr transfer (-12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-12-05 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 73 certified glazing combinations for 1372/1374 Single Slider/3-Lite End Vent (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 31 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 27 packages (1 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 38 packages (1 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 38 packages (5 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
United Window & Door Mfg., Inc. — 9600 Horizontal Slider Vinyl 0.20 0.13 66
Soft-Lite, LLC — Elements DSL20 Slider Vinyl 0.20 0.17 60
Soft-Lite, LLC — Imperial Elite DSL12E Vinyl 0.20 0.17 60
Walsh Building Products — 6100 Double Slider Vinyl 0.20 0.18 59
Thompson Creek Window Company — 7900 Double Hung Vinyl 0.20 0.17 88

What other certified series does North Star Manufacturing (London) Ltd. produce?

Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent appear below.

What U-Factor and SHGC range does North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent achieve?

North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent spans 73 certified configurations with U-Factors between 0.20 and 0.28 and SHGC values from 0.16 to 0.54. Ranked #671 of 1,352 Window families, it carries 5 Most Efficient options.

Which glazing options in North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent meet Northern climate limits?

Yes. 31 packages in North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

What conductive BTU/hr difference separates 1372/1374 Single Slider/3-Lite End Vent from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1372/1374 Single Slider/3-Lite End Vent at U 0.20 conducts 120.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make 1372/1374 Single Slider/3-Lite End Vent the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1372/1374 Single Slider/3-Lite End Vent options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in 1372/1374 Single Slider/3-Lite End Vent?

Yes. 38 Southern-certified options inside North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.54 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside 1372/1374 Single Slider/3-Lite End Vent qualifies as Most Efficient?

EPA lists 5 Most Efficient options (6.8% share) inside North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent, out of 73 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect 1372/1374 Single Slider/3-Lite End Vent?

Any 1372/1374 Single Slider/3-Lite End Vent purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify 1372/1374 Single Slider/3-Lite End Vent after sticker removal?

Match the NFRC thermal sticker for code NSM and line NSM-A-14 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. 1372/1374 Single Slider/3-Lite End Vent come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros