Skip to main content
Window · Vinyl Frame NFRC UWD · Product Line UWD-M-59

United Window & Door Mfg., Inc. — 3800 / 3900 Series Fixed Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 111 variants inside United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window, combining Vinyl frame construction with U-Factors spanning 0.23 to 0.32 and SHGC 0.19 to 0.54. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #936 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.23
SHGC Range
0.19-0.54
Certified Options
111
Category Standing
#936 of 1,352

How does United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window compare thermally against Window peers?

United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3800 / 3900 Series Fixed WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 3800 / 3900 Series Fixed Window (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3800 / 3900 Series Fixed Window Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window at rank #936 of 1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.19-0.54 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 20 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-10-03 licensing and 2025-03-26 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 111 certified glazing combinations for 3800 / 3900 Series Fixed Window (NFRC UWD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 20 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 52 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 36 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 62 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does United Window & Door Mfg., Inc. produce?

Compare other active United Window & Door Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window appear below.

What thermal performance numbers separate United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window from peers?

Built with Vinyl framing in Fixed Window (FIXD) style, United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window offers 111 Version 7.0 configurations from U 0.23 up to 0.32, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

Does United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern approval ends at U <= 0.22, above 3800 / 3900 Series Fixed Window's 0.23 minimum. However, 20 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

What BTU/hr heat transfer results from 3800 / 3900 Series Fixed Window's 0.23 minimum U-Factor?

At U 0.23, a standard 3x5 ft (15 sq ft) 3800 / 3900 Series Fixed Window opening transfers 138.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +6.0 BTU/hr difference.

What homeowner profiles are a poor match for United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 3800 / 3900 Series Fixed Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many 3800 / 3900 Series Fixed Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 62 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window, while total line SHGC reaches 0.54 in colder packages.

Which package tier in 3800 / 3900 Series Fixed Window holds Most Efficient recognition?

Zero glazing builds inside 3800 / 3900 Series Fixed Window's 111 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 3800 / 3900 Series Fixed Window window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 3800 / 3900 Series Fixed Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on 3800 / 3900 Series Fixed Window?

Match the NFRC thermal sticker for code UWD and line UWD-M-59 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for United Window & Door Mfg., Inc. 3800 / 3900 Series Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)