Skip to main content
Window · Vinyl Frame NFRC NTW · Product Line NTW-A-13

NT Window, Inc. — E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH · Single Hung

NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.23 across 112 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.13 to 0.21.

Min U-Factor
0.23
SHGC Range
0.13-0.21
Certified Options
112
Category Standing
#936 of 1,352

How does NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH compare thermally against Window peers?

NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SHHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.13 to 0.21) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-04-25.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 112 certified glazing combinations for E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 29 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 75 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 112 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH appear below.

What thermal performance numbers separate NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH from peers?

EPA ENERGY STAR v7.0 records 112 configurations for NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH covering North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH in cold Northern ENERGY STAR counties?

No. Because E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

How much winter heat loss does E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.

Which situations make E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH in Southern or South-Central zones?

Yes, E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH holds 112 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

How many NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH variants earn ENERGY STAR Most Efficient?

E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH holds zero Most Efficient entries across its 112 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 NT Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH after sticker removal?

Verify NFRC ID NTW and series NTW-A-13 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros