Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-133 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Legend Casement · Casement Windows

Across 82 Windsor Windows and Doors certified families, Legend Casement supplies 660 Casement Windows configurations starting at 0.22 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.44 SHGC. Its thermal floor ranks #831 of 1,352 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.14-0.44
Certified Options
660
Category Standing
#831 of 1,352

How does Windsor Windows and Doors Legend Casement compare thermally against Window peers?

Windsor Windows and Doors Legend Casement achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Legend CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Legend Casement (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Legend Casement Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 82 certified Windsor Windows and Doors series, this Casement Windows offers a 0.10 U-Factor adjustment span between 0.32 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).

Mapping NFRC SHGC values (0.14 to 0.44) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 9 configurations meet ENERGY STAR Most Efficient criteria while 36 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-17.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 660 certified glazing combinations for Legend Casement (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 36 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 92 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 290 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 622 packages (9 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Legend Casement appear below.

How efficient is Windsor Windows and Doors Legend Casement compared with peer Window models?

Built with Wood framing in Casement Single-Vent (CSSV) style, Windsor Windows and Doors Legend Casement offers 660 Version 7.0 configurations from U 0.22 up to 0.32, posting +0.02 against the Window median of 0.20 with 9 Most Efficient picks.

How does Windsor Windows and Doors Legend Casement satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 36 Legend Casement packages (U floor 0.22, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates Legend Casement from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying Legend Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Legend Casement options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Legend Casement?

Warm-climate homeowners have 622 Southern-approved options within Legend Casement spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 660 Legend Casement configurations ENERGY STAR Most Efficient?

Only 9 options out of 660 (1.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in Windsor Windows and Doors Legend Casement, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Legend Casement?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Windsor Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Legend Casement after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.22-0.32, SHGC 0.14-0.44) against permit drawings for line WIN-N-133. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Legend Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros