Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-114 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Pinnacle Clad Casement Picture · Picture Window

Positioning #831/1,352 in certified Window, Windsor Windows and Doors Pinnacle Clad Casement Picture pairs Wood frame construction with 528 glazing options rated between 0.16 and 0.51 SHGC across Northern, North-Central, South-Central, Southern. Across 82 certified Windsor Windows and Doors product families, its thermal resistance spans 0.22 to 0.32 U-Factor and the line includes 2 ENERGY STAR Most Efficient packages (0.4% of line).

Min U-Factor
0.22
SHGC Range
0.16-0.51
Certified Options
528
Category Standing
#831 of 1,352

How does Windsor Windows and Doors Pinnacle Clad Casement Picture compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Clad Casement Picture achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Clad Casement PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Pinnacle Clad Casement Picture (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Clad Casement Picture Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Pinnacle Clad Casement Picture is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.22-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 2 configurations meet ENERGY STAR Most Efficient criteria while 42 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors WIN to 2024-02-16 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 528 certified glazing combinations for Pinnacle Clad Casement Picture (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 42 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 88 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 257 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 485 packages (2 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Casement Picture appear below.

Where does Windsor Windows and Doors Pinnacle Clad Casement Picture stand thermally among ENERGY STAR Window lines?

Across 528 tested NFRC glazing configurations, Windsor Windows and Doors Pinnacle Clad Casement Picture with Wood framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.16-0.51 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

Is Pinnacle Clad Casement Picture approved for Northern Zone heating climates?

Yes, 42 packages satisfy Northern ENERGY STAR Version 7.0 rules in Pinnacle Clad Casement Picture. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft Pinnacle Clad Casement Picture window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Windsor Windows and Doors Pinnacle Clad Casement Picture?

Do not specify Pinnacle Clad Casement Picture without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Casement Picture options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is Pinnacle Clad Casement Picture suitable for sunbelt cooling-dominated homes?

Yes. 485 Southern-certified options inside Windsor Windows and Doors Pinnacle Clad Casement Picture satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.51 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside Pinnacle Clad Casement Picture qualifies as Most Efficient?

No. Exactly 2 of 528 configurations (0.4%) earn ENERGY STAR Most Efficient status in Pinnacle Clad Casement Picture; the remaining standard v7.0 options pass base zone limits only.

Can homeowners claim Form 5695 credits on Windsor Windows and Doors Pinnacle Clad Casement Picture in 2026?

Any Pinnacle Clad Casement Picture purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Clad Casement Picture units match permits?

Match the NFRC thermal sticker for code WIN and line WIN-N-114 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros