Skip to main content
Window · Other Frame NFRC WIN · Product Line WIN-N-137

Windsor Windows and Doors — Pinnacle Clad French & Narrow Sliding Door Stationary Panel · Sidelite

Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel is a Sidelite assembly with a Other frame that reaches a minimum U-Factor of 0.25 across 72 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.39.

Min U-Factor
0.25
SHGC Range
0.12-0.39
Certified Options
72
Category Standing
#1,174 of 1,352

How does Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Clad French & Narrow Sliding Door Stationary PanelHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Pinnacle Clad French & Narrow Sliding Door Stationary Panel (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Clad French & Narrow Sliding Door Stationary Panel Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Other cohort (0.25 median U-Factor), Pinnacle Clad French & Narrow Sliding Door Stationary Panel reaches 0.25 on its lowest-conductivity package — #5 of 12 in Other, tied with 2 others at 0.25, more insulating than 41.7% of Other lines (At median vs Other peers). Pairing NFRC ID WIN across multi-pane fills shifts U-Factor from 0.28 down toward 0.25.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 20 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-17. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 72 certified glazing combinations for Pinnacle Clad French & Narrow Sliding Door Stationary Panel (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 20 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 20 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 70 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 70 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Essential Double Hung Fiberglass 0.25 0.19 78
Marvin — Essential Glider Fiberglass 0.25 0.19 78
Marvin — Essential Single Hung Fiberglass 0.25 0.19 78
Hometime Windows & Doors — 1600 Fixed Vinyl 0.25 0.15 58
Trinity Glass International — Modern Fiberglass Inswing / Outswing Sidelite Vinyl / Wood 0.25 0.04 56

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel appear below.

What thermal performance numbers separate Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel from peers?

Built with Other framing in Fixed Sidelite (FXSL) style, Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel offers 72 Version 7.0 configurations from U 0.25 up to 0.28, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

Can homeowners install Pinnacle Clad French & Narrow Sliding Door Stationary Panel in cold Northern ENERGY STAR counties?

Because Pinnacle Clad French & Narrow Sliding Door Stationary Panel starts at 0.25 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 20 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How does a 3x5 ft Pinnacle Clad French & Narrow Sliding Door Stationary Panel window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pinnacle Clad French & Narrow Sliding Door Stationary Panel at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad French & Narrow Sliding Door Stationary Panel options exceeding U 0.22. Verify whether your municipal code restricts Other frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Pinnacle Clad French & Narrow Sliding Door Stationary Panel?

Across Northern, North-Central, South-Central, Southern, 70 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel, while total line SHGC reaches 0.39 in colder packages.

Are all 72 Pinnacle Clad French & Narrow Sliding Door Stationary Panel configurations ENERGY STAR Most Efficient?

Zero glazing builds inside Pinnacle Clad French & Narrow Sliding Door Stationary Panel's 72 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Do 2026 Pinnacle Clad French & Narrow Sliding Door Stationary Panel installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Pinnacle Clad French & Narrow Sliding Door Stationary Panel retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify Pinnacle Clad French & Narrow Sliding Door Stationary Panel after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line WIN-N-137 and NFRC ID WIN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door Stationary Panel come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros