Skip to main content
Window · Other Frame NFRC WIN · Product Line WIN-N-119 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Pinnacle Primed Casement · Casement Windows

Positioning #831/1,352 in certified Window, Windsor Windows and Doors Pinnacle Primed Casement pairs Other frame construction with 610 glazing options rated between 0.14 and 0.44 SHGC across Northern, North-Central, South-Central, Southern. Across 82 certified Windsor Windows and Doors product families, its thermal resistance spans 0.22 to 0.32 U-Factor and the line includes 6 ENERGY STAR Most Efficient packages (1.0% of line).

Min U-Factor
0.22
SHGC Range
0.14-0.44
Certified Options
610
Category Standing
#831 of 1,352

How does Windsor Windows and Doors Pinnacle Primed Casement compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Primed Casement achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Primed CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Pinnacle Primed Casement (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Primed Casement Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Other cohort (0.25 median U-Factor), Pinnacle Primed Casement reaches 0.22 on its lowest-conductivity package — #2 of 12 in Other, more insulating than 83.3% of Other lines, top 16.7% (-0.03 vs Other peers). Pairing NFRC ID WIN across multi-pane fills shifts U-Factor from 0.32 down toward 0.22.

Regional qualification covers Northern, North-Central, South-Central, Southern. 6 configurations meet ENERGY STAR Most Efficient criteria while 27 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors WIN to 2024-02-20 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 610 certified glazing combinations for Pinnacle Primed Casement (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 27 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 103 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 301 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 578 packages (6 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Pella Corporation — Impervia Fixed Fiberglass 0.22 0.13 602
Soft-Lite, LLC — Classic Plus DSL10P Slider Vinyl 0.22 0.15 632
Value Windows & Doors — IM-PW-2106 Vinyl 0.22 0.14 665
Soft-Lite, LLC — Classic Plus DH10P Double Hung Vinyl 0.22 0.15 477
Pella Corporation — Impervia Shapes Fiberglass / Vinyl 0.22 0.14 744

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Primed Casement appear below.

How well does Pinnacle Primed Casement by Windsor Windows and Doors insulate relative to Window benchmarks?

Testing puts Windsor Windows and Doors Pinnacle Primed Casement at rank #831 of 1,352 Window entries with U 0.22 to 0.32 across 610 configurations. Solar heat gain ranges between 0.14 and 0.44 across Northern, North-Central, South-Central, Southern.

Can homeowners install Pinnacle Primed Casement in cold Northern ENERGY STAR counties?

Cold-climate buyers get 27 compliant Northern packages inside Pinnacle Primed Casement, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from Pinnacle Primed Casement's 0.22 minimum U-Factor?

Using NFRC WIN U-Factor 0.22, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).

What homeowner profiles are a poor match for Windsor Windows and Doors Pinnacle Primed Casement?

Skip Pinnacle Primed Casement if local historic preservation boards prohibit Other profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Primed Casement options exceeding U 0.22.

Does Pinnacle Primed Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Pinnacle Primed Casement holds 578 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

Are all 610 Pinnacle Primed Casement configurations ENERGY STAR Most Efficient?

EPA lists 6 Most Efficient options (1.0% share) inside Windsor Windows and Doors Pinnacle Primed Casement, out of 610 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Windsor Windows and Doors Pinnacle Primed Casement in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Pinnacle Primed Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Pinnacle Primed Casement glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-119, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Primed Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros