Specialty Wholesale Supply — 9 ENERGY STAR v7.0 Certified Series
Specialty Wholesale Supply registers 9 active product series in EPA ENERGY STAR Version 7.0 (5 Doors, 4 Windows), spanning 785,707 certified NFRC glazing configurations across Steel / Wood, Vinyl, Wood frames. Whole-unit U-Factors span 0.13 down to 0.32 with 2 Most Efficient lines and regional qualification across North-Central, Northern, South-Central, Southern, meeting the <= 0.3 cfm/ft2 air leakage ceiling. Closely matched thermal competitors include EnergyWall Window (10 series, min U 0.13).
- Certified Series
- 9 lines
- Most Efficient Lines
- 2 series
- Min / Max U-Factor
- 0.13 – 0.32
- Primary Frames
- Steel / Wood, Vinyl, Wood
Which 9 certified Specialty Wholesale Supply product lines qualify under ENERGY STAR v7.0?
Filter all 9 certified Specialty Wholesale Supply series below; click any product line to inspect U-Factor histograms, SHGC ranges, and zone compliance matrices.
| Series & Product Type | Category | Frame Material | Min U-Factor | SHGC Band | Qualified Zones |
|---|---|---|---|---|---|
| Wood Edge Steel Entry/Patio Door Swinging Entry Door (Single) |
Door | Wood | 0.13 | 0.01–0.32 | Northern, North-Central, South-Central, Southern |
| Fiberglass Entry/Patio Door Swinging Entry Door (Single) |
Door | Wood | 0.15 | 0.01–0.33 | Northern, North-Central, South-Central, Southern |
| Fiberglass Sidelite Sidelite |
Window | Wood | 0.15 | 0.01–0.19 | Northern, North-Central, South-Central, Southern |
| Wood Edge Steel Sidelite Sidelite |
Window | Wood | 0.15 | 0.01–0.19 | Northern, North-Central, South-Central, Southern |
| Metal Edge/Steel Entry Door Swinging Entry Door (Single) |
Door | Steel / Wood | 0.16 | 0.01–0.29 | Northern, North-Central, South-Central, Southern |
| 7000/7500 TrustGard Casement Casement Windows |
Window | Vinyl | 0.19 | 0.07–0.43 | Northern, North-Central, South-Central, Southern |
| 7100/7600 TrustGard Awning Awning (Projected) |
Window | Vinyl | 0.19 | 0.17–0.43 | Northern, North-Central, South-Central, Southern |
| 1100/1200/1300 Corsair Patio Door Sliding Patio Door |
Door | Vinyl | 0.23 | 0.07–0.25 | Northern, North-Central, South-Central, Southern |
| 1001/1005/1006 Patio Door Sliding Patio Door |
Door | Vinyl | 0.25 | 0.07–0.27 | Northern, North-Central, South-Central, Southern |
Catalog Breadth: Specialty Wholesale Supply covers North-Central, Northern, South-Central, Southern with 785,707 individual glass-spacer combinations across 5 Doors, 4 Windows.
Thermal Spread: Choosing triple-pane or argon Low-E upgrades inside Specialty Wholesale Supply's catalog lowers assembly U-Factor from 0.32 down to 0.13.
How do peer ENERGY STAR manufacturers compare to Specialty Wholesale Supply?
Compare six peer ENERGY STAR fenestration manufacturers sitting closest to Specialty Wholesale Supply's 0.13 minimum U-Factor and active series count below.
North Star Manufacturing (London) Ltd.
Primary frames: Vinyl · 11 Most Efficient lines.
What should buyers verify before ordering Specialty Wholesale Supply units?
Verify glass package order codes, IRC R310 bedroom egress clear widths, and sill flashing details before signing Specialty Wholesale Supply installation contracts.
Baseline SKUs vs. zone-qualified Low-E glass
Even within Specialty Wholesale Supply's catalog, entry double-pane units near U 0.32 often fail Northern v7.0 limits; verify the exact NFRC order sheet.
What thermal, warranty, and NFRC questions matter for Specialty Wholesale Supply?
Direct answers addressing ENERGY STAR climate zone compliance, frame material durability, Northern thresholds, and quote checks for Specialty Wholesale Supply appear below.
How low does Specialty Wholesale Supply's ENERGY STAR v7.0 U-Factor go?
Specialty Wholesale Supply reaches a 0.13 minimum U-Factor across its 9 active certified lines (785,707 total tested glass options), with 2 Most Efficient series.
Which frame materials does Specialty Wholesale Supply certify under ENERGY STAR?
Active Specialty Wholesale Supply filings span Steel / Wood, Vinyl, Wood across 5 Doors, 4 Windows.
Does Specialty Wholesale Supply meet Northern <= 0.22 U-Factor limits?
Yes—select configurations reach U <= 0.22 for cold Northern climates.
What should buyers verify on Specialty Wholesale Supply window quotes?
Confirm exact NFRC CPD series ID, glass Low-E tier, IRC R310 bedroom egress opening dimensions, and pre-1978 EPA Lead RRP installer status.
Which official federal and state sources back this page?
Every Specialty Wholesale Supply series count, frame designation, and NFRC thermal performance boundary resolves directly to official EPA ENERGY STAR ProductFinder filings.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)