Andersen Corporation — 100 Series/Series 2 Awning Window · Awning (Projected)
Across 111 Andersen Corporation certified families, 100 Series/Series 2 Awning Window supplies 1,827 Awning, Projected configurations starting at 0.18 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.42 SHGC. Its thermal floor ranks #477 of 1,352 category entries—0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.18
- SHGC Range
- 0.12-0.42
- Certified Options
- 1,827
- Category Standing
- #477 of 1,352
How does Andersen Corporation 100 Series/Series 2 Awning Window compare thermally against Window peers?
Andersen Corporation 100 Series/Series 2 Awning Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation 100 Series/Series 2 Awning Window standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Composite profiles alone (median 0.22) shows -0.04 before selecting Low-E tiers.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 390 configurations meet ENERGY STAR Most Efficient criteria while 266 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-06-06.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,827 certified glazing combinations for 100 Series/Series 2 Awning Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 266 packages (138 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 776 packages (279 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 1,045 packages (195 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,567 packages (306 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Interstate Building Materials, Inc. — 1750/9800 Direct Set Fixed | Composite | 0.18 | 0.16 | 1,203 |
| Sierra Pacific Windows — H3 2.0 Direct Set | Wood | 0.18 | 0.11 | 1,846 |
| Windsor Windows and Doors — Next Dimension Awning | Vinyl | 0.18 | 0.11 | 1,872 |
| Windsor Windows and Doors — Next Dimension Casement | Vinyl | 0.18 | 0.11 | 1,939 |
| Harvey Industries, Inc. — Classic / Pro100 Double Hung | Vinyl | 0.18 | 0.17 | 1,965 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Awning Window appear below.
What U-Factor and SHGC range does Andersen Corporation 100 Series/Series 2 Awning Window achieve?
Built with Composite framing in Projected Awning (PRAW) style, Andersen Corporation 100 Series/Series 2 Awning Window offers 1,827 Version 7.0 configurations from U 0.18 up to 0.32, posting -0.02 against the Window median of 0.20 with 390 Most Efficient picks.
Which glazing options in Andersen Corporation 100 Series/Series 2 Awning Window meet Northern climate limits?
Yes. 266 packages in Andersen Corporation 100 Series/Series 2 Awning Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How do you calculate winter heat conduction for Andersen Corporation 100 Series/Series 2 Awning Window?
At U 0.18, a standard 3x5 ft (15 sq ft) 100 Series/Series 2 Awning Window opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.
Who should NOT choose Andersen Corporation 100 Series/Series 2 Awning Window for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Awning Window options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Is 100 Series/Series 2 Awning Window suitable for sunbelt cooling-dominated homes?
Across Northern, North-Central, South-Central, Southern, 1,567 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 100 Series/Series 2 Awning Window, while total line SHGC reaches 0.42 in colder packages.
How many Andersen Corporation 100 Series/Series 2 Awning Window variants earn ENERGY STAR Most Efficient?
No. Exactly 390 of 1,827 configurations (21.3%) earn ENERGY STAR Most Efficient status in 100 Series/Series 2 Awning Window; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to 100 Series/Series 2 Awning Window?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 100 Series/Series 2 Awning Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
What permanent glass etch marks verify 100 Series/Series 2 Awning Window after sticker removal?
Match the NFRC thermal sticker for code AND and line AND-N-85 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Awning Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)