Skip to main content
Window · Composite Frame NFRC AND · Product Line AND-N-85 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 100 Series/Series 2 Awning Window · Awning (Projected)

Across 111 Andersen Corporation certified families, 100 Series/Series 2 Awning Window supplies 1,827 Awning, Projected configurations starting at 0.18 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.42 SHGC. Its thermal floor ranks #477 of 1,352 category entries—0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.18
SHGC Range
0.12-0.42
Certified Options
1,827
Category Standing
#477 of 1,352

How does Andersen Corporation 100 Series/Series 2 Awning Window compare thermally against Window peers?

Andersen Corporation 100 Series/Series 2 Awning Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 100 Series/Series 2 Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 100 Series/Series 2 Awning Window (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

100 Series/Series 2 Awning Window Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation 100 Series/Series 2 Awning Window standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Composite profiles alone (median 0.22) shows -0.04 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 390 configurations meet ENERGY STAR Most Efficient criteria while 266 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-06-06.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,827 certified glazing combinations for 100 Series/Series 2 Awning Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 266 packages (138 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 776 packages (279 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,045 packages (195 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,567 packages (306 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Awning Window appear below.

What U-Factor and SHGC range does Andersen Corporation 100 Series/Series 2 Awning Window achieve?

Built with Composite framing in Projected Awning (PRAW) style, Andersen Corporation 100 Series/Series 2 Awning Window offers 1,827 Version 7.0 configurations from U 0.18 up to 0.32, posting -0.02 against the Window median of 0.20 with 390 Most Efficient picks.

Which glazing options in Andersen Corporation 100 Series/Series 2 Awning Window meet Northern climate limits?

Yes. 266 packages in Andersen Corporation 100 Series/Series 2 Awning Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Andersen Corporation 100 Series/Series 2 Awning Window?

At U 0.18, a standard 3x5 ft (15 sq ft) 100 Series/Series 2 Awning Window opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

Who should NOT choose Andersen Corporation 100 Series/Series 2 Awning Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Awning Window options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 100 Series/Series 2 Awning Window suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 1,567 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 100 Series/Series 2 Awning Window, while total line SHGC reaches 0.42 in colder packages.

How many Andersen Corporation 100 Series/Series 2 Awning Window variants earn ENERGY STAR Most Efficient?

No. Exactly 390 of 1,827 configurations (21.3%) earn ENERGY STAR Most Efficient status in 100 Series/Series 2 Awning Window; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to 100 Series/Series 2 Awning Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 100 Series/Series 2 Awning Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 100 Series/Series 2 Awning Window after sticker removal?

Match the NFRC thermal sticker for code AND and line AND-N-85 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros