Andersen Corporation — 100 Series/ Series 2 Double Hung Window · Double Hung
Positioning #1,174/1,352 in certified Window, Andersen Corporation 100 Series/ Series 2 Double Hung Window pairs Composite frame construction with 1,130 glazing options rated between 0.15 and 0.47 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.25 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.
- Min U-Factor
- 0.25
- SHGC Range
- 0.15-0.47
- Certified Options
- 1,130
- Category Standing
- #1,174 of 1,352
How does Andersen Corporation 100 Series/ Series 2 Double Hung Window compare thermally against Window peers?
Andersen Corporation 100 Series/ Series 2 Double Hung Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Composite cohort (0.22 median U-Factor), 100 Series/ Series 2 Double Hung Window reaches 0.25 on its lowest-conductivity package — #13 of 21 in Composite, tied with 3 others at 0.25, more insulating than 23.8% of Composite lines (+0.03 vs Composite peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.
Mapping NFRC SHGC values (0.15 to 0.47) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 34 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-02-04.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,130 certified glazing combinations for 100 Series/ Series 2 Double Hung Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 34 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 66 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 307 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,096 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Krestmark Industries L. P. — 200/220/275 Single Hung | Vinyl | 0.25 | 0.11 | 1,065 |
| Silver Line Building Products — 8601 Double Hung | Vinyl | 0.25 | 0.17 | 1,209 |
| Amsco Windows — VS1 (Studio) Single Hung | Vinyl | 0.25 | 0.13 | 1,038 |
| YKK AP America, Inc. — Style View/Style View Classic Single Hung Archtop | Vinyl | 0.25 | 0.18 | 1,016 |
| JELD-WEN, inc. — Brickmould Vinyl (V-3700) Tilt Single Hung | Vinyl | 0.25 | 0.13 | 1,310 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/ Series 2 Double Hung Window appear below.
How efficient is Andersen Corporation 100 Series/ Series 2 Double Hung Window compared with peer Window models?
Andersen Corporation 100 Series/ Series 2 Double Hung Window spans 1,130 certified configurations with U-Factors between 0.25 and 0.32 and SHGC values from 0.15 to 0.47. Ranked #1,174 of 1,352 Window families, it carries 0 Most Efficient options.
Can homeowners install 100 Series/ Series 2 Double Hung Window in cold Northern ENERGY STAR counties?
With a 0.25 minimum U-Factor, Andersen Corporation 100 Series/ Series 2 Double Hung Window cannot satisfy prescriptive <= 0.22 Northern targets, yet 34 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.
What conductive BTU/hr difference separates 100 Series/ Series 2 Double Hung Window from the 0.22 Northern rule?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on 100 Series/ Series 2 Double Hung Window's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
What are the practical limitations of specifying 100 Series/ Series 2 Double Hung Window?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/ Series 2 Double Hung Window options exceeding U 0.22. Verify whether your municipal code restricts Composite frames in wildfire or historic zones.
How many 100 Series/ Series 2 Double Hung Window glazing packages pass Southern solar-heat rules?
Warm-climate homeowners have 1,096 Southern-approved options within 100 Series/ Series 2 Double Hung Window spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in 100 Series/ Series 2 Double Hung Window holds Most Efficient recognition?
ENERGY STAR Most Efficient designation is absent across all 1,130 100 Series/ Series 2 Double Hung Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What 2026 federal tax credit and Lead RRP rules apply to 100 Series/ Series 2 Double Hung Window?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 100 Series/ Series 2 Double Hung Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
What permanent glass etch marks verify 100 Series/ Series 2 Double Hung Window after sticker removal?
Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.15-0.47) against permit drawings for line AND-N-239. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/ Series 2 Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)