Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-19

Andersen Corporation — 400 Series Gliding Window · Double Slider

With a minimum U-Factor of 0.26—+0.06 compared against the 0.20 Window median—Andersen Corporation 400 Series Gliding Window spans 566 tested options across South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.13 and 0.23.

Min U-Factor
0.26
SHGC Range
0.13-0.23
Certified Options
566
Category Standing
#1,256 of 1,352

How does Andersen Corporation 400 Series Gliding Window compare thermally against Window peers?

Andersen Corporation 400 Series Gliding Window achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Gliding WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 400 Series Gliding Window (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Gliding Window Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 400 Series Gliding Window spans 566 NFRC test records (AND), ranking #1,256 of 1,352 Window families (tied with 35 others at 0.26, more insulating than 4.5% of Window lines). Its 0.26 thermal floor compares at +0.05 against the Wood median (0.21).

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2024-03-20 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 566 certified glazing combinations for 400 Series Gliding Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 106 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 566 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Gliding Window appear below.

What thermal performance numbers separate Andersen Corporation 400 Series Gliding Window from peers?

Built with Wood framing in Dual-Slide Horizontal (HSXX) style, Andersen Corporation 400 Series Gliding Window offers 566 Version 7.0 configurations from U 0.26 up to 0.32, posting +0.06 against the Window median of 0.20 with 0 Most Efficient picks.

Does Andersen Corporation 400 Series Gliding Window qualify for the ENERGY STAR Northern Zone?

No. Because 400 Series Gliding Window reaches only 0.26 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across South-Central, Southern cooling or mixed markets.

How does a 3x5 ft 400 Series Gliding Window window perform under a 40 deg F temperature drop?

Using NFRC AND U-Factor 0.26, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

What homeowner profiles are a poor match for Andersen Corporation 400 Series Gliding Window?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Gliding Window options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in 400 Series Gliding Window?

Warm-climate homeowners have 566 Southern-approved options within 400 Series Gliding Window spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 400 Series Gliding Window qualifies as Most Efficient?

400 Series Gliding Window holds zero Most Efficient entries across its 566 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Gliding Window?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 400 Series Gliding Window glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-19 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Gliding Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)