Andersen Corporation — 400 Series Woodwright Curved-Top Hung Full-Frame Windows · Double Hung
Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.24 across 300 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.15 to 0.46.
- Min U-Factor
- 0.24
- SHGC Range
- 0.15-0.46
- Certified Options
- 300
- Category Standing
- #1,034 of 1,352
How does Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows compare thermally against Window peers?
Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.03 before selecting Low-E tiers.
Mapping NFRC SHGC values (0.15 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 5 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2026-09-25.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 300 certified glazing combinations for 400 Series Woodwright Curved-Top Hung Full-Frame Windows (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 5 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 25 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 97 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 286 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Weather Shield Mfg., Inc. — 8217 Push-Out Casement / French Casement | Wood | 0.24 | 0.11 | 306 |
| Weather Shield Mfg., Inc. — 8218/1212 French Casement | Wood | 0.24 | 0.11 | 335 |
| Marvin — Elevate Glider | Wood | 0.24 | 0.17 | 402 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Double Hung Sash Set Transom Extruded(UED5E1642) | Wood | 0.24 | 0.11 | 410 |
| Lincoln Wood Products, Inc. — Wood Casement Studio | Wood | 0.24 | 0.17 | 149 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows appear below.
What thermal performance numbers separate Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows from peers?
Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows spans 300 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.15 to 0.46. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
How does Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows satisfy Version 7.0 Northern criteria?
Because 400 Series Woodwright Curved-Top Hung Full-Frame Windows starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 5 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
How do you calculate winter heat conduction for Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 400 Series Woodwright Curved-Top Hung Full-Frame Windows's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
Which situations make 400 Series Woodwright Curved-Top Hung Full-Frame Windows the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Woodwright Curved-Top Hung Full-Frame Windows options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Does 400 Series Woodwright Curved-Top Hung Full-Frame Windows meet Southern hot-climate SHGC caps (<= 0.23)?
Exactly 286 400 Series Woodwright Curved-Top Hung Full-Frame Windows options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.46 glass.
Are all 300 400 Series Woodwright Curved-Top Hung Full-Frame Windows configurations ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 300 400 Series Woodwright Curved-Top Hung Full-Frame Windows options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What federal compliance checks govern 2026 400 Series Woodwright Curved-Top Hung Full-Frame Windows window swaps?
Any 400 Series Woodwright Curved-Top Hung Full-Frame Windows purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How can homeowners confirm delivered Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows units match permits?
Match the NFRC thermal sticker for code AND and line AND-N-111 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Woodwright Curved-Top Hung Full-Frame Windows come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)