Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-216 ENERGY STAR Most Efficient Eligible

Andersen Corporation — A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set · Transom

Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set is a Transom assembly with a Wood frame that reaches a minimum U-Factor of 0.22 across 3,322 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.34.

Min U-Factor
0.22
SHGC Range
0.11-0.34
Certified Options
3,322
Category Standing
#831 of 1,352

How does Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set compare thermally against Window peers?

Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A-Series Frenchwood® Patio Door Sidelight/Transom – Sash SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set reaches 0.22 on its lowest-conductivity package — #207 of 408 in Wood, tied with 38 others at 0.22, more insulating than 40.0% of Wood lines (+0.01 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.22.

Mapping NFRC SHGC values (0.11 to 0.34) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 19 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-04-09 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,322 certified glazing combinations for A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 175 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 964 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,290 packages (19 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set appear below.

How efficient is Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set compared with peer Window models?

EPA ENERGY STAR v7.0 records 3,322 configurations for Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 19 options earn Most Efficient status.

Can homeowners install A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set in cold Northern ENERGY STAR counties?

Yes. 12 packages in Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set the wrong window or door choice?

Do not specify A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 3,290 Southern-approved options within A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set holds Most Efficient recognition?

Only 19 options out of 3,322 (0.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-216 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Frenchwood® Patio Door Sidelight/Transom – Sash Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros