Andersen Corporation — A-Series Specialty Windows - Direct-Set · Picture Window
Andersen Corporation A-Series Specialty Windows - Direct-Set is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.16 across 2,333 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.53.
- Min U-Factor
- 0.16
- SHGC Range
- 0.16-0.53
- Certified Options
- 2,333
- Category Standing
- #250 of 1,352
How does Andersen Corporation A-Series Specialty Windows - Direct-Set compare thermally against Window peers?
Andersen Corporation A-Series Specialty Windows - Direct-Set achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 111 certified Andersen Corporation series, this Picture Window offers a 0.16 U-Factor adjustment span between 0.32 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).
Climate coverage for Andersen Corporation A-Series Specialty Windows - Direct-Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 712 configurations meet ENERGY STAR Most Efficient criteria while 808 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,333 certified glazing combinations for A-Series Specialty Windows - Direct-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 808 packages (344 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,123 packages (624 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 985 packages (312 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,754 packages (400 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Kolbe and Kolbe Millwork Co., Inc — Heritage Push Out Awning MPL & SPL | Wood | 0.16 | 0.08 | 1,730 |
| Sierra Pacific Windows — Clad Direct Set | Wood | 0.16 | 0.10 | 2,962 |
| Sierra Pacific Windows — Clad Aspen Casement | Wood | 0.16 | 0.09 | 1,629 |
| Sierra Pacific Windows — Clad Aspen Awning | Wood | 0.16 | 0.09 | 1,620 |
| Marvin — Ultimate Wood Double Hung Picture 2inch Sash | Wood | 0.16 | 0.10 | 1,597 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Specialty Windows - Direct-Set appear below.
What thermal performance numbers separate Andersen Corporation A-Series Specialty Windows - Direct-Set from peers?
Built with Wood framing in Fixed Window (FIXD) style, Andersen Corporation A-Series Specialty Windows - Direct-Set offers 2,333 Version 7.0 configurations from U 0.16 up to 0.32, posting -0.04 against the Window median of 0.20 with 712 Most Efficient picks.
Can homeowners install A-Series Specialty Windows - Direct-Set in cold Northern ENERGY STAR counties?
Cold-climate buyers get 808 compliant Northern packages inside A-Series Specialty Windows - Direct-Set, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
How do you calculate winter heat conduction for Andersen Corporation A-Series Specialty Windows - Direct-Set?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on A-Series Specialty Windows - Direct-Set's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
Which situations make A-Series Specialty Windows - Direct-Set the wrong window or door choice?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Specialty Windows - Direct-Set options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
Is A-Series Specialty Windows - Direct-Set suitable for sunbelt cooling-dominated homes?
Warm-climate homeowners have 1,754 Southern-approved options within A-Series Specialty Windows - Direct-Set spanning SHGC down to 0.16. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside A-Series Specialty Windows - Direct-Set qualifies as Most Efficient?
EPA lists 712 Most Efficient options (30.5% share) inside Andersen Corporation A-Series Specialty Windows - Direct-Set, out of 2,333 total Version 7.0 entries.
How do the 25C sunset and pre-1978 Lead RRP rules affect A-Series Specialty Windows - Direct-Set?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current A-Series Specialty Windows - Direct-Set retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How can homeowners confirm delivered Andersen Corporation A-Series Specialty Windows - Direct-Set units match permits?
Match the NFRC thermal sticker for code AND and line AND-N-126 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Specialty Windows - Direct-Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)