Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-177 ENERGY STAR Most Efficient Eligible

Andersen Corporation — E-Series Casement/Push Out Casement Windows · Casement Windows

Positioning #831/1,352 in certified Window, Andersen Corporation E-Series Casement/Push Out Casement Windows pairs Wood frame construction with 9,194 glazing options rated between 0.13 and 0.39 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.22 to 0.32 U-Factor and the line includes 20 ENERGY STAR Most Efficient packages (0.2% of line).

Min U-Factor
0.22
SHGC Range
0.13-0.39
Certified Options
9,194
Category Standing
#831 of 1,352

How does Andersen Corporation E-Series Casement/Push Out Casement Windows compare thermally against Window peers?

Andersen Corporation E-Series Casement/Push Out Casement Windows achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E-Series Casement/Push Out Casement WindowsHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing E-Series Casement/Push Out Casement Windows (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E-Series Casement/Push Out Casement Windows Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across E-Series Casement/Push Out Casement Windows spans 9,194 NFRC test records (AND), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.01 against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 20 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2019-01-08 licensing and 2025-02-04 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 9,194 certified glazing combinations for E-Series Casement/Push Out Casement Windows (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 14 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 560 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,934 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 9,012 packages (20 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Casement/Push Out Casement Windows appear below.

Where does Andersen Corporation E-Series Casement/Push Out Casement Windows stand thermally among ENERGY STAR Window lines?

Built with Wood framing in Casement Single-Vent (CSSV) style, Andersen Corporation E-Series Casement/Push Out Casement Windows offers 9,194 Version 7.0 configurations from U 0.22 up to 0.32, posting +0.02 against the Window median of 0.20 with 20 Most Efficient picks.

Can homeowners install E-Series Casement/Push Out Casement Windows in cold Northern ENERGY STAR counties?

Yes. 14 packages in Andersen Corporation E-Series Casement/Push Out Casement Windows clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What BTU/hr heat transfer results from E-Series Casement/Push Out Casement Windows's 0.22 minimum U-Factor?

At U 0.22, a standard 3x5 ft (15 sq ft) E-Series Casement/Push Out Casement Windows opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

Who should NOT choose Andersen Corporation E-Series Casement/Push Out Casement Windows for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Casement/Push Out Casement Windows options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does E-Series Casement/Push Out Casement Windows meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 9,012 Southern-approved options within E-Series Casement/Push Out Casement Windows spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside E-Series Casement/Push Out Casement Windows qualifies as Most Efficient?

EPA lists 20 Most Efficient options (0.2% share) inside Andersen Corporation E-Series Casement/Push Out Casement Windows, out of 9,194 total Version 7.0 entries.

What federal compliance checks govern 2026 E-Series Casement/Push Out Casement Windows window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on E-Series Casement/Push Out Casement Windows?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-177, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Casement/Push Out Casement Windows come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros