Andersen Corporation — E-Series Fixed Arch Casement Window - Sash Set (2-Piece) · Picture Window
Positioning #831/1,352 in certified Window, Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) pairs Wood frame construction with 3,881 glazing options rated between 0.07 and 0.44 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.22 to 0.32 U-Factor and the line includes 24 ENERGY STAR Most Efficient packages (0.6% of line).
- Min U-Factor
- 0.22
- SHGC Range
- 0.07-0.44
- Certified Options
- 3,881
- Category Standing
- #831 of 1,352
How does Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) compare thermally against Window peers?
Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.01 before selecting Low-E tiers.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 24 configurations meet ENERGY STAR Most Efficient criteria while 46 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2024-04-09. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 3,881 certified glazing combinations for E-Series Fixed Arch Casement Window - Sash Set (2-Piece) (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 46 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 150 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 688 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 3,815 packages (24 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Sierra Pacific Windows — Aluminum Clad Outswing Transom | Wood | 0.22 | 0.09 | 1,739 |
| Marvin — Ultimate Wood Double Hung Transom | Wood | 0.22 | 0.11 | 1,687 |
| Sierra Pacific Windows — Monument Single Hung - Double Hung | Wood | 0.22 | 0.09 | 1,398 |
| JELD-WEN, inc. — Custom Wood Epic Double Hung Picture | Wood | 0.22 | 0.10 | 1,142 |
| Sierra Pacific Windows — Monument Horizontal Slider | Wood | 0.22 | 0.10 | 1,089 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) appear below.
What U-Factor and SHGC range does Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) achieve?
Built with Wood framing in Fixed Window (FIXD) style, Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) offers 3,881 Version 7.0 configurations from U 0.22 up to 0.32, posting +0.02 against the Window median of 0.20 with 24 Most Efficient picks.
Is E-Series Fixed Arch Casement Window - Sash Set (2-Piece) approved for Northern Zone heating climates?
Cold-climate buyers get 46 compliant Northern packages inside E-Series Fixed Arch Casement Window - Sash Set (2-Piece), reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
How much winter heat loss does E-Series Fixed Arch Casement Window - Sash Set (2-Piece) conduct across a 15 sq ft opening?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on E-Series Fixed Arch Casement Window - Sash Set (2-Piece)'s lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
Which situations make E-Series Fixed Arch Casement Window - Sash Set (2-Piece) the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Fixed Arch Casement Window - Sash Set (2-Piece) options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 3,815 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece), while total line SHGC reaches 0.44 in colder packages.
Does E-Series Fixed Arch Casement Window - Sash Set (2-Piece) carry EPA Most Efficient certification across its lineup?
Within E-Series Fixed Arch Casement Window - Sash Set (2-Piece), 0.6% (24 of 3,881) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
What 2026 federal tax credit and Lead RRP rules apply to E-Series Fixed Arch Casement Window - Sash Set (2-Piece)?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do you cross-check NFRC AND and product line AND-N-161 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-161, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Fixed Arch Casement Window - Sash Set (2-Piece) come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)