Skip to main content
Window · Composite Frame NFRC AND · Product Line AND-N-102 ENERGY STAR Most Efficient Eligible

Andersen Corporation — Renewal by Andersen? Casement Window · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 3,173 variants inside Andersen Corporation Renewal by Andersen? Casement Window, combining Composite frame construction with U-Factors spanning 0.20 to 0.32 and SHGC 0.13 to 0.41. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #671 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.22 Btu/hr·ft²·°F median among Composite peers.

Min U-Factor
0.20
SHGC Range
0.13-0.41
Certified Options
3,173
Category Standing
#671 of 1,352

How does Andersen Corporation Renewal by Andersen? Casement Window compare thermally against Window peers?

Andersen Corporation Renewal by Andersen? Casement Window achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Renewal by Andersen? Casement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Renewal by Andersen? Casement Window (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Renewal by Andersen? Casement Window Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 111 certified Andersen Corporation series, this Casement Windows offers a 0.12 U-Factor adjustment span between 0.32 entry options and 0.20 top-performing glazing. Category standing is #671/1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines).

Regional qualification covers Northern, North-Central, South-Central, Southern. 55 configurations meet ENERGY STAR Most Efficient criteria while 86 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2024-03-12.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,173 certified glazing combinations for Renewal by Andersen? Casement Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 86 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 374 packages (17 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,329 packages (16 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,047 packages (54 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Renewal by Andersen? Casement Window appear below.

Where does Andersen Corporation Renewal by Andersen? Casement Window stand thermally among ENERGY STAR Window lines?

Andersen Corporation Renewal by Andersen? Casement Window spans 3,173 certified configurations with U-Factors between 0.20 and 0.32 and SHGC values from 0.13 to 0.41. Ranked #671 of 1,352 Window families, it carries 55 Most Efficient options.

Does Andersen Corporation Renewal by Andersen? Casement Window qualify for the ENERGY STAR Northern Zone?

Yes, 86 packages satisfy Northern ENERGY STAR Version 7.0 rules in Renewal by Andersen? Casement Window. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Andersen Corporation Renewal by Andersen? Casement Window?

Using NFRC AND U-Factor 0.20, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).

When should a buyer skip Andersen Corporation Renewal by Andersen? Casement Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Renewal by Andersen? Casement Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in Renewal by Andersen? Casement Window?

Yes. 3,047 Southern-certified options inside Andersen Corporation Renewal by Andersen? Casement Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.41 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Andersen Corporation Renewal by Andersen? Casement Window variants earn ENERGY STAR Most Efficient?

EPA lists 55 Most Efficient options (1.7% share) inside Andersen Corporation Renewal by Andersen? Casement Window, out of 3,173 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Andersen Corporation Renewal by Andersen? Casement Window in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Renewal by Andersen? Casement Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Renewal by Andersen? Casement Window glass specs on job sites?

Verify NFRC ID AND and series AND-N-102 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Renewal by Andersen? Casement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)