Andersen Corporation — Renewal by Andersen® Entry Door – Direct Set Transom · Transom
With a minimum U-Factor of 0.18—-0.02 compared against the 0.20 Window median—Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom spans 1,811 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Composite assembly includes 248 ENERGY STAR Most Efficient packages (13.7% of line) and offers SHGC packages between 0.15 and 0.53.
- Min U-Factor
- 0.18
- SHGC Range
- 0.15-0.53
- Certified Options
- 1,811
- Category Standing
- #477 of 1,352
How does Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom compare thermally against Window peers?
Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 111 certified Andersen Corporation series, this Transom offers a 0.14 U-Factor adjustment span between 0.32 entry options and 0.18 top-performing glazing. Category standing is #477/1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 248 configurations meet ENERGY STAR Most Efficient criteria while 456 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2024-03-05.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,811 certified glazing combinations for Renewal by Andersen® Entry Door – Direct Set Transom (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 456 packages (100 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 800 packages (176 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 873 packages (100 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,291 packages (160 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Interstate Building Materials, Inc. — 1750/9800 Direct Set Fixed | Composite | 0.18 | 0.16 | 1,203 |
| Sierra Pacific Windows — H3 2.0 Direct Set | Wood | 0.18 | 0.11 | 1,846 |
| Windsor Windows and Doors — Next Dimension Awning | Vinyl | 0.18 | 0.11 | 1,872 |
| Windsor Windows and Doors — Next Dimension Casement | Vinyl | 0.18 | 0.11 | 1,939 |
| Harvey Industries, Inc. — Classic / Pro100 Double Hung | Vinyl | 0.18 | 0.17 | 1,965 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom appear below.
Where does Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom stand thermally among ENERGY STAR Window lines?
EPA ENERGY STAR v7.0 records 1,811 configurations for Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.20 Window median. Only 248 options earn Most Efficient status.
How does Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom satisfy Version 7.0 Northern criteria?
Yes. 456 packages in Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How does a 3x5 ft Renewal by Andersen® Entry Door – Direct Set Transom window perform under a 40 deg F temperature drop?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make Renewal by Andersen® Entry Door – Direct Set Transom the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Renewal by Andersen® Entry Door – Direct Set Transom options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Is Renewal by Andersen® Entry Door – Direct Set Transom suitable for sunbelt cooling-dominated homes?
Yes, Renewal by Andersen® Entry Door – Direct Set Transom holds 1,291 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.
What glazing share inside Renewal by Andersen® Entry Door – Direct Set Transom qualifies as Most Efficient?
Only 248 options out of 1,811 (13.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom, usually requiring triple-pane or upgraded Low-E coatings.
Do 2026 Renewal by Andersen® Entry Door – Direct Set Transom installations qualify for IRS Section 25C tax credits?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Renewal by Andersen® Entry Door – Direct Set Transom installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do building inspectors verify Renewal by Andersen® Entry Door – Direct Set Transom glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.18-0.32, SHGC 0.15-0.53) against permit drawings for line AND-N-234. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Transom come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)