Andersen Corporation — Residential Clad Entry Door Transom - Inswing; Sash-Set · Picture Window
Across 111 Andersen Corporation certified families, Residential Clad Entry Door Transom - Inswing; Sash-Set supplies 47,802 Picture Window configurations starting at 0.18 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.46 SHGC. Its thermal floor ranks #477 of 1,352 category entries—0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.18
- SHGC Range
- 0.11-0.46
- Certified Options
- 47,802
- Category Standing
- #477 of 1,352
How does Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set compare thermally against Window peers?
Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Wood profiles alone (median 0.21) shows -0.03 before selecting Low-E tiers.
Climate coverage for Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 2,825 configurations meet ENERGY STAR Most Efficient criteria while 2,051 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2024-08-08.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 47,802 certified glazing combinations for Residential Clad Entry Door Transom - Inswing; Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 2,051 packages (372 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 8,912 packages (883 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 15,733 packages (669 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 45,505 packages (2,608 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Ultimate Wood Casement | Wood | 0.18 | 0.10 | 31,500 |
| Marvin — Ultimate Wood Awning | Wood | 0.18 | 0.09 | 16,890 |
| Marvin — Ultimate Wood Casement Push Out | Wood | 0.18 | 0.10 | 13,808 |
| Quaker Window Products — W600/W300 Fixed | Wood | 0.18 | 0.13 | 10,577 |
| Marvin — Ultimate Glider | Wood | 0.18 | 0.11 | 9,660 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set appear below.
Where does Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set stand thermally among ENERGY STAR Window lines?
Testing puts Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set at rank #477 of 1,352 Window entries with U 0.18 to 0.32 across 47,802 configurations. Solar heat gain ranges between 0.11 and 0.46 across Northern, North-Central, South-Central, Southern.
Does Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set qualify for the ENERGY STAR Northern Zone?
Yes. 2,051 packages in Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How much winter heat loss does Residential Clad Entry Door Transom - Inswing; Sash-Set conduct across a 15 sq ft opening?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Who should NOT choose Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Residential Clad Entry Door Transom - Inswing; Sash-Set options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Is Residential Clad Entry Door Transom - Inswing; Sash-Set suitable for sunbelt cooling-dominated homes?
Yes, Residential Clad Entry Door Transom - Inswing; Sash-Set holds 45,505 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.
Does Residential Clad Entry Door Transom - Inswing; Sash-Set carry EPA Most Efficient certification across its lineup?
EPA lists 2,825 Most Efficient options (5.9% share) inside Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set, out of 47,802 total Version 7.0 entries.
How do the 25C sunset and pre-1978 Lead RRP rules affect Residential Clad Entry Door Transom - Inswing; Sash-Set?
Any Residential Clad Entry Door Transom - Inswing; Sash-Set purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify Residential Clad Entry Door Transom - Inswing; Sash-Set after sticker removal?
Verify NFRC ID AND and series AND-N-145 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Residential Clad Entry Door Transom - Inswing; Sash-Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)