Andersen Corporation — Residential Wood Entry Door Transom - Inswing; Sash-Set · Picture Window
Andersen Corporation engineered the Residential Wood Entry Door Transom - Inswing; Sash-Set Picture Window line for Northern, North-Central, South-Central, Southern, certifying 17,285 glass-spacer combinations from 0.22 to 0.32 U-Factor and 0.11 to 0.46 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.01 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.22
- SHGC Range
- 0.11-0.46
- Certified Options
- 17,285
- Category Standing
- #831 of 1,352
How does Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set compare thermally against Window peers?
Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.01 before selecting Low-E tiers.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 36 configurations meet ENERGY STAR Most Efficient criteria while 115 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2025-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 17,285 certified glazing combinations for Residential Wood Entry Door Transom - Inswing; Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 115 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 1,785 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 5,283 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 16,708 packages (36 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Siteline Clad Wood (W-5500) Double Hung Fixed Insash | Wood | 0.22 | 0.11 | 11,473 |
| Sierra Pacific Windows — Aluminum Clad Outswing Transom | Wood | 0.22 | 0.09 | 1,739 |
| Marvin — Ultimate Wood Double Hung Transom | Wood | 0.22 | 0.11 | 1,687 |
| Sierra Pacific Windows — Monument Single Hung - Double Hung | Wood | 0.22 | 0.09 | 1,398 |
| JELD-WEN, inc. — Custom Wood Epic Double Hung Picture | Wood | 0.22 | 0.10 | 1,142 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set appear below.
How well does Residential Wood Entry Door Transom - Inswing; Sash-Set by Andersen Corporation insulate relative to Window benchmarks?
Across 17,285 tested NFRC glazing configurations, Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set with Wood framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.11-0.46 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.
Is Residential Wood Entry Door Transom - Inswing; Sash-Set approved for Northern Zone heating climates?
Cold-climate buyers get 115 compliant Northern packages inside Residential Wood Entry Door Transom - Inswing; Sash-Set, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
How much winter heat loss does Residential Wood Entry Door Transom - Inswing; Sash-Set conduct across a 15 sq ft opening?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Who should NOT choose Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set for a residential project?
Skip Residential Wood Entry Door Transom - Inswing; Sash-Set if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Residential Wood Entry Door Transom - Inswing; Sash-Set options exceeding U 0.22.
How many Residential Wood Entry Door Transom - Inswing; Sash-Set glazing packages pass Southern solar-heat rules?
Yes. 16,708 Southern-certified options inside Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.
Does Residential Wood Entry Door Transom - Inswing; Sash-Set carry EPA Most Efficient certification across its lineup?
No. Exactly 36 of 17,285 configurations (0.2%) earn ENERGY STAR Most Efficient status in Residential Wood Entry Door Transom - Inswing; Sash-Set; the remaining standard v7.0 options pass base zone limits only.
What federal compliance checks govern 2026 Residential Wood Entry Door Transom - Inswing; Sash-Set window swaps?
Any Residential Wood Entry Door Transom - Inswing; Sash-Set purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How can homeowners confirm delivered Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-137 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Residential Wood Entry Door Transom - Inswing; Sash-Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)