Andersen Corporation — Residential Wood Entry Door Transom - Outswing; Sash-Set · Picture Window
Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.22 across 17,464 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.46.
- Min U-Factor
- 0.22
- SHGC Range
- 0.11-0.46
- Certified Options
- 17,464
- Category Standing
- #831 of 1,352
How does Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set compare thermally against Window peers?
Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Residential Wood Entry Door Transom - Outswing; Sash-Set reaches 0.22 on its lowest-conductivity package — #207 of 408 in Wood, tied with 38 others at 0.22, more insulating than 40.0% of Wood lines (+0.01 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.22.
Regional qualification covers Northern, North-Central, South-Central, Southern. 36 configurations meet ENERGY STAR Most Efficient criteria while 118 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2025-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 17,464 certified glazing combinations for Residential Wood Entry Door Transom - Outswing; Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 118 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 1,818 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 5,326 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 16,897 packages (36 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Siteline Clad Wood (W-5500) Double Hung Fixed Insash | Wood | 0.22 | 0.11 | 11,473 |
| Sierra Pacific Windows — Aluminum Clad Outswing Transom | Wood | 0.22 | 0.09 | 1,739 |
| Marvin — Ultimate Wood Double Hung Transom | Wood | 0.22 | 0.11 | 1,687 |
| Sierra Pacific Windows — Monument Single Hung - Double Hung | Wood | 0.22 | 0.09 | 1,398 |
| JELD-WEN, inc. — Custom Wood Epic Double Hung Picture | Wood | 0.22 | 0.10 | 1,142 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set appear below.
How well does Residential Wood Entry Door Transom - Outswing; Sash-Set by Andersen Corporation insulate relative to Window benchmarks?
EPA ENERGY STAR v7.0 records 17,464 configurations for Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 36 options earn Most Efficient status.
Is Residential Wood Entry Door Transom - Outswing; Sash-Set approved for Northern Zone heating climates?
Cold-climate buyers get 118 compliant Northern packages inside Residential Wood Entry Door Transom - Outswing; Sash-Set, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What BTU/hr heat transfer results from Residential Wood Entry Door Transom - Outswing; Sash-Set's 0.22 minimum U-Factor?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on Residential Wood Entry Door Transom - Outswing; Sash-Set's lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
What homeowner profiles are a poor match for Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set?
Skip Residential Wood Entry Door Transom - Outswing; Sash-Set if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Residential Wood Entry Door Transom - Outswing; Sash-Set options exceeding U 0.22.
Can you install Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set in Southern or South-Central zones?
Yes. 16,897 Southern-certified options inside Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.
What glazing share inside Residential Wood Entry Door Transom - Outswing; Sash-Set qualifies as Most Efficient?
No. Exactly 36 of 17,464 configurations (0.2%) earn ENERGY STAR Most Efficient status in Residential Wood Entry Door Transom - Outswing; Sash-Set; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to Residential Wood Entry Door Transom - Outswing; Sash-Set?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on Residential Wood Entry Door Transom - Outswing; Sash-Set?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-140, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Residential Wood Entry Door Transom - Outswing; Sash-Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)